Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693MDL740
IC693MDL740 GE Fanuc Series 90-30 Positive Logic Output
Manufacturer: General Electric
Product No.: IC693MDL740
Product Type: Positive Logic Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693MDL740 is a 12/24 Volt DC Positive Logic (Sourcing) Discrete Output Module designed for the versatile Series 90-30 Programmable Logic Controller system. Featuring 16 high-speed output points arranged in two isolated groups of 8, this module supplies positive power directly from an external supply to connected load devices such as solenoids, indicators, relays, and motor starters. Weighing 0.35 kg (0.77 lbs), the IC693MDL740 offers an efficient single-slot form factor with built-in optocoupler isolation to protect backplane logic from field-side voltage transients.
Core Technical Advantages
- High-Speed Sourcing Outputs: Delivers up to 0.5 Amps per channel across 16 output points with a swift 2 ms maximum ON/OFF response time, ideal for real-time process control.
- High Inrush Handling: Built to withstand inductive load surges, supporting up to 4.78 Amperes of peak inrush current per group for 10 milliseconds.
- Low Backplane Power Draw: Consumes a maximum of 110 mA from the internal 5V DC bus, preserving backplane power for adjacent I/O modules and processors.
- Clear Field Diagnostics: Features 16 green LED status indicators on the front panel, providing immediate visual verification of channel logic states for easy troubleshooting.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc / Emerson Automation (Series 90-30) |
| Model Part Number | IC693MDL740 |
| Module Net Weight | 0.35 kg (0.77 lbs) |
| Module Type | Discrete Output Module (Positive Logic / Sourcing) |
| Output Point Count | 16 points (2 isolated commons, 8 points per common) |
| Nominal Output Voltage | 12/24 Volts DC (+20% / -15% operating range) |
| Output Current Rating | 0.5 A maximum per point (2.0 A max per common group) |
| Peak Inrush Surge Current | 4.78 Amperes per point maximum for 10 ms duration |
| ON / OFF Response Time | 2 ms maximum for both ON and OFF states |
| Backplane Current Draw | 110 mA maximum from the 5V DC backplane bus |
| Isolation Rating | 1500V RMS optical isolation field-to-backplane |
| Relative Humidity Range | 5% to 95% (non-condensing) |
Installation & Wiring Guidelines
- Baseplate Slot Insertion: Align the 0.35 kg module with the card guides in any standard I/O slot of a Series 90-30 baseplate. Press firmly until the module is fully seated into the backplane, and swing the top/bottom retaining tabs into place.
- Field Supply Connections: Connect the external +12/24V DC user power supply to the designated common terminals on the front terminal block. Verify correct polarity—positive logic requires the module to source positive voltage to the loads.
- Inductive Load Suppression: When switching inductive loads like DC solenoids or relays, place a flyback diode directly across the load terminals to prevent back-EMF voltage spikes from damaging the output transistors.
Technical FAQs
Q1: What is the difference between positive logic (sourcing) and negative logic (sinking) on the IC693MDL740?
A1: The IC693MDL740 is a positive logic (sourcing) module, meaning its internal transistors switch positive voltage from the user power supply directly to the field load. Sinking (negative logic) modules, by contrast, switch the ground/negative side of the load.
Q2: Can I run 12V DC loads on one group and 24V DC loads on the other group?
A2: Yes. The 16 output points are divided into two separate, isolated groups of 8 points, each with its own common connection. This allows you to wire different external supply voltages to each group independently.
Q3: Does the IC693MDL740 require external user power to operate the output points?
A3: Yes. While the module's internal logic is powered by 110 mA from the PLC's 5V DC backplane, the actual field output currents (up to 0.5A per point) must be supplied by an external 12/24V DC field power supply.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Achieve Deterministic Multi-Unit Coordination in GE Systems?
This article examines real-world communication bottlenecks in multi-unit industrial facilities using GE control syste...
-
Why Does Your Plant Need GE Intelligent Operation Platform Now?
This article explores how the GE Intelligent Operation Platform addresses fragmented asset workflows in industri...
-
Can Remote Vibration Monitoring Cut Rotating Machinery Downtime?
This article examines how Bently Nevada remote data transmission addresses the high cost of unplanned rotating machin...
-
Why Does Poor Sensor Data Ruin Predictive Maintenance Outcomes?
Field signal quality forms the foundation of predictive maintenance success in industrial automation. Despite signifi...
-
Can Modular Control Architecture Eliminate Batch Process Variability?
This article examines how ABB modular control architecture resolves batch process variability through ISA-S88 complia...
-
Remote Monitoring: Fixing Multi-Site Control Bottlenecks?
This article analyzes why legacy industrial control architectures create operational bottlenecks across multi-site fa...
