Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693CPU311
IC693CPU311 GE Fanuc 90-30 | Embedded CPU Baseplate 10 MHz
Manufacturer: General Electric
Product No.: IC693CPU311
Product Type: CPU Baseplate
Product Origin: USA
Payment:T/T, Western Union
Weight: 540g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
GE Fanuc IC693CPU311 Embedded CPU Baseplate is a central processing unit for the Series 90-30 family. This 10 MHz CPU delivers 6 KB of user memory. It handles complex logic operations with an 18 ms scan rate per 1K of Boolean logic.
Core Specifications
| Clock Speed | 10 MHz |
| Processor Speed | 10 MHz |
| User Memory | 6 KB |
| Analog Outputs | 32 Words (%AQ) |
Performance Metrics
| Typical Scan Rate | 18 ms per 1K of Boolean logic |
| Boolean Execution Speed | 18 ms per 1K logic |
| Current Load | 410 mA |
Physical Attributes
| Dimensions | 30.48 × 30.48 × 30.48 cm (12 × 12 × 12 inches) |
| Weight | 0.54 kg (1.19 lbs) |
Operating Conditions
| Operating Temperature | 32°F to 140°F (0°C to 60°C) |
| Storage Temperature | -40°F to 185°F (-40°C to 85°C) |
| Humidity | 5% to 95% non-condensing |
Installation Guide
Mount the IC693CPU311 in the Series 90-30 baseplate. Connect the power supply to the backplane. The CPU draws 410 mA from the 5V bus. Ensure operating temperature remains between 32°F and 140°F for reliable operation. The compact 12-inch cube design fits standard 90-30 racks.
Engineering Advantages
The IC693CPU311 delivers 18 ms scan rate per 1K of Boolean logic for efficient program execution. 6 KB user memory handles moderate logic applications. 32 words of analog output (%AQ) provide flexible control capabilities. The embedded CPU design simplifies installation and reduces cabinet space requirements.
FAQs
Q1: How much memory is available for user logic?
A1: The IC693CPU311 provides 6 KB of user memory for ladder logic and configuration.
Q2: What is the maximum number of I/O points this CPU supports?
A2: The CPU supports up to 512 discrete I/O points and 32 words of analog output (%AQ).
Q3: Can this CPU be upgraded to newer firmware?
A3: Firmware is fixed on the IC693CPU311. For expanded memory and features, consider the IC693CPU313 or CPU331.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can GE Fanuc-Emerson Integration Cut OPEX 18%?
A regional refinery cut downtime 28% and energy use 18% via GE Fanuc PLC-Emerson DCS integration. Retained legacy har...
-
Why Do 78% of Digital Retrofits Fail Without Edge Data?
This technical article examines how Emerson's industrial edge gateway resolves multi-vendor OT interoperability chall...
-
Brand-New PLC CPUs for Aging Coal Chemical Plants?
This technical article presents a data-driven upgrade strategy for aging GE Fanuc PLC CPUs in coal chemical facilitie...
-
Cross-Vendor PLC/DCS Integration for Auto MES?
This article presents field-validated MES docking methodologies for multi-vendor PLC and DCS environments in discrete...
-
AB PLC Dropping EIP Links with Bently 3500?
This field-validated guide addresses EtherNet/IP communication failures between Allen‑Bradley Logix PLCs and Bently N...
-
What is the best zero-downtime automation strategy for mega steelworks?
This article presents a hybrid multi-brand control system retrofit for large blast furnaces, integrating ABB DCS, GE ...