Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693ALG220
IC693ALG220 High Precision Analog Input GE Fanuc Series 90-30
Manufacturer: General Electric
Product No.: IC693ALG220
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC693ALG220 Analog Voltage Input Module
Product Overview
IC693ALG220 is a 4 channel analog voltage input module for GE Fanuc Series 90-30 PLC systems. Provides precise voltage measurements from -10 to +10 Volts. Factory calibrated for improved accuracy. Module weight 0.45 kg.
Technical Specifications
| Parameter | Value |
|---|---|
| Voltage Range | -10 to +10 Volts |
| Calibration | Factory calibrated |
| Update Rate | 4 ms (all 4 channels) |
| Resolution | 5 mV (1 LSB = 5 mV) |
| Absolute Accuracy (Typical) | ±10 mV over operating temperature |
| Absolute Accuracy (Maximum) | ±30 mV over operating temperature |
| Linearity | Less than 1 LSB |
| Isolation | 1500 Volts field to logic side |
| Cross Channel Rejection | Greater than 80 dB |
| Input Impedance (Voltage Mode) | Greater than 9 MΩ |
| Input Impedance (Current Mode) | 250 Ω |
| Input Filter Response | 17 Hz |
| Internal Power (+5V bus) | 27 mA |
| Internal Power (+24V isolated bus) | 98 mA |
| Weight | 0.45 kg |
Key Features
- 4 analog input channels
- -10 to +10 Volt input range
- Factory calibrated for improved accuracy
- 4 ms update rate for all channels
- 5 mV resolution
- 1500 Volt isolation field to logic side
- Greater than 80 dB cross channel rejection
- 17 Hz input filter response for optimal signal quality
Compatible Systems
GE Fanuc Series 90-30 PLC systems including CPU311, CPU313, CPU323, CPU331, CPU340, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363 and compatible 90-30 expansion racks.
FAQs
Q1: What is the voltage measurement range of IC693ALG220?
A1: The module measures -10 to +10 Volts DC with 5 mV resolution.
Q2: How fast is the update rate?
A2: 4 milliseconds for all four channels simultaneously.
Q3: What isolation does this module provide?
A3: 1500 Volts isolation between field side and logic side for reliable operation in industrial environments.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
-
How Does ABB Fieldbus Cut Industrial Automation Wiring Costs?
ABB fieldbus instruments reduce cable costs by 40-55% and enable real-time DCS diagnostics, yet 62% of faults stem fr...
-
Can Wireless Gas Detection Fix Hard-to-Reach Plant Blind Spots?
This article reviews how the Honeywell Universal Transmitter enables wireless gas detection in hard-to-reach hazardou...
