Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC660EBD024
IC660EBD024 32-Circuit DC I/O Assembly - GE Fanuc
Manufacturer: General Electric
Product No.: IC660EBD024
Product Type: I/O Block
Product Origin: USA
Payment:T/T, Western Union
Weight: 1800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GENIUS IC660EBD024 Electronic Assembly
The IC660EBD024 is a Genius I/O assembly by GE Fanuc. It provides 32-circuit DC I/O for industrial control systems.
Technical Specifications
- Brand & Model: GE Fanuc IC660EBD024
- I/O Circuits: 32 Isolated I/O Circuits
- Voltage Range: 10-30 VDC (12/24VDC Source)
- Output Current: 0.5 Amps per circuit
- Block Current: 16 Amps total
- Isolation: 850 V Block-to-Block
- Power Requirement: 150 mA typical, 300 mA max
- Weight: 1.8 kg (4 lbs)
Electrical Specifications
- Heat Dissipation: 11W (8 inputs), 18W (32 outputs)
- Turn-on Delay: 0.5 microseconds maximum
- Diagnostics: Switch Fault detection
- Circuit Type: Source I/O configuration
Environmental Specs
- Operating Temp: 0°C to 60°C
- Storage Temp: -40°C to 100°C
- Humidity: 5-95% non-condensing
Key Features
- 32 configurable I/O circuits
- 12/24VDC source operation
- 850V isolation for safety
- 0.5A per circuit capacity
- Switch fault diagnostics
- Heat dissipation management
Configuration
- I/O Type: Source configuration
- Logic States: On-state = Logic 1, Off-state = Logic 0
- Circuit Flexibility: Each circuit configurable as input or output
- Power Connection: Outputs connect to negative supply side
Package Contents
- IC660EBD024 electronic assembly
- Technical documentation
- Wiring diagram available separately
Frequently Asked Questions
How many circuits does it have?
- It has 32 isolated I/O circuits. Each circuit can be configured as either input or output.
What is the current capacity?
- 0.5 Amps per circuit, 16 Amps total block current. The IC660EBD024 handles moderate current loads.
What are the heat specifications?
- Heat dissipation: 11W with 8 inputs, 18W with 32 outputs at 0.5A each. Proper heat management is required.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...