Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200CBL545
IC200CBL545 GE Fanuc VersaMax CPU001 DataPanel Cable
Manufacturer: General Electric
Product No.: IC200CBL545
Product Type: Communication Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 550g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC200CBL545 VersaMax CPU001 RS-232 Communication Cable
The GE Fanuc IC200CBL545 is a serial communication cable designed for the VersaMax CPU001 to DataPanel 3x/5x connection. Weighing 0.55 kg, it features a 9-pin D-sub connector and supports RS-232 serial communication for reliable data exchange between PLC and operator interface [citation:4][citation:6].
Product Identification
- Manufacturer: GE Fanuc
- Part Number: IC200CBL545
- Product Type: Serial Communication Cable
- Compatible CPU: VersaMax CPU001
- Connection: DataPanel 3x/5x
Technical Specifications
| Parameter | Value |
|---|---|
| Weight | 0.55 kg |
| Connector Type | 9-pin D-sub (DE-9) |
| Communication Protocol | RS-232 |
| Compatible CPU | VersaMax CPU001 |
| Target Device | DataPanel 3x/5x |
Pinout and Signal Information
The DE-9 connector on the VersaMax CPU001 Port 1 follows the IBM-PC/AT convention. The pin assignments are as follows [citation:6]:
- Pin 2 (RXD): Output from CPU
- Pin 3 (TXD): Input to CPU
- Pin 5 (GND): Ground
- Pin 7 (RTS): Output from CPU
- Pin 8 (CTS): Input to CPU
Cable Specifications
For RS-232 communication, the maximum cable length is 15 meters (50 feet). The cable should be shielded to minimize electrical noise interference [citation:5]. The recommended cable type includes 5-conductor, 24 AWG tinned copper with braid over foil shield [citation:5].
Connection and Compatibility
- Connects VersaMax CPU001 to DataPanel 3x/5x operator interfaces.
- Supports RS-232 serial communication for data exchange.
- DE-9 D-sub connector with standard pinout.
- Weight: 0.55 kg for reliable cable management.
Technical FAQs
Q1: What is the maximum RS-232 cable length for the VersaMax CPU001?
A1: Maximum length is 15 meters (50 feet) for RS-232 communication [citation:5].
Q2: Does the IC200CBL545 require a null-modem connection?
A2: Yes. For connection to a PC COM port, use a null-modem cable that crosses pins 2↔3 [citation:6].
Q3: What is the weight of this cable?
A3: 0.55 kg [citation:4].
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Do Default Bently Nevada Thresholds Trigger 71.8% Nuisance Alarms?
This technical article examines why factory-default Bently Nevada 3500 vibration thresholds frequently fail in real-w...
-
How to Optimize Spare Parts Sourcing for Honeywell Gas Detection?
This article presents a structured approach to sourcing Honeywell gas detection spares for industrial automation syst...
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
