Skip to content
Automation parts, worldwide supply
Skip to product information
1 of 3

SKU:FC-TDOL-07120

Honeywell FC-TDOL-07120 Digital Output Module

Only 2 units left
  • Manufacturer: Honeywell

  • Product No.: FC-TDOL-07120

  • Product Type: Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1200g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The FC-TDOL-07120 (general type FS-TDOL-07120) is a 7-channel line-monitored Field Termination Assembly (FTA) module designed for the Honeywell Safety Manager system. This module serves as a heavy-duty power interface for critical field loads requiring 120Vac or 120Vdc digital outputs. Equipped with 7 fused relay contact outputs, it bridges low-voltage control logic with high-capacity field equipment, providing integrated loop diagnostics and high galvanic isolation for emergency shutdown and critical control loops.

Core Technical Advantages

  • Advanced Line Monitoring: Integrates dedicated surveillance circuits across all 7 output channels to detect open and short circuits in field wiring.
  • High-Capacity Switching: Features robust onboard relays supporting industrial field loads up to 240VA (AC) or 150W (DC) per channel.
  • Cross-Module Interconnection: Connects seamlessly with SDO-0824 output and SDI-1624 input modules via standard system cables to drive logic and process faults.
  • Visual Diagnostics: Includes dedicated status LEDs for each relay channel, allowing instantaneous visual verification of output states during maintenance.

Technical Specifications

Parameter Specification Details
Model Number FC-TDOL-07120 / FS-TDOL-07120
Channel Count 7 Digital Output Channels
Output Supply Voltage 120V AC or 120V DC (+/- 20%)
Max Output Current 2A per channel (at 120V AC)
Maximum Channel Load 240VA (Resistive/Inductive) or 150W
Channel Protection 2A individual channel fuses
Expected Relay Life 100,000 electrical operations / 30,000,000 mechanical operations
Mounting Options DIN EN rails: TS32 / TS35 x 7.5
Dimensions (L x W x H) 240 x 109 x 71 mm
Approvals CE, UL, CSA, TUV

Installation & Maintenance Guide

Module Wiring and Interconnection

Interface the module to the upstream control layers using dedicated system interconnection cables. Connect channels 1 through 7 of the SDO-0824 module to control the respective output relays, and wire the integrated line-monitoring outputs back to channels 1 through 15 of the SDI-1624 input module.

DIN Rail Mounting

Snap the rugged housing securely onto standard DIN EN rails (compatible with TS32 or TS35 × 7.5 profiles). Ensure sufficient clearance around the assembly inside the enclosure to facilitate heat dissipation from inductive loads and allow clear visibility of the relay state LEDs.

Fuse and Service Safeties

Each output channel is individually isolated by a 2A fuse. If a field short-circuit occurs, isolate the main 120V power source before extracted or replacing the blown fuse. Always execute test operations via the application logic to verify loop feedback integrity post-replacement.

Engineering Advantages

  • Universal Load Capability: Formulated to switch both inductive and resistive industrial field loads safely without requiring external snubber circuits.
  • High Operational Lifespan: Heavy-duty relay construction delivers up to 30 million mechanical cycles, lowering total cost of ownership and minimizing downtime.
  • Full Safety Compliance: Backed by CE, UL, CSA, and TUV certifications, ensuring seamless deployment within strict regulatory and SIL-rated environments.

Technical FAQs

Q1: How does the line-monitoring feature operate on this module?
A1: Line-monitoring circuits on each channel track field loop continuity. This diagnostic routing is activated by channel 8 of the SDO-0824 module and processed via channels 1 to 15 of the SDI-1624 input module using specialized application logic.

Q2: Can I mix 120V AC and 120V DC loads on the same module?
A2: While the contacts are rated for both 120V AC and 120V DC (+/- 20%), it is standard engineering practice to maintain consistent voltage types across a single physical board to prevent cross-contamination of power rails.

Q3: What is the maximum switched power rating for the contacts?
A3: The relay contacts support a maximum switched power threshold of 1250VA for alternating current loops and 60 Watts for direct current safety loops.

🏷️ Tags: Output Module
  • DC-powered
  • Compact
  • Modular

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.