Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:FC-PSU-UNI6020U
Honeywell FC-PSU-UNI6020U 60V 20A Power Supply
Manufacturer: Honeywell
Product No.: FC-PSU-UNI6020U
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 5700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
60V 20A Industrial Power Supply
Honeywell FC-PSU-UNI6020U delivers 60V DC at 20A for industrial applications. This UL508 approved supply provides stable power for demanding systems.
Key Features
- Dual OVP: Complies with DIN V 19250 and VDE V 0801 safety standards.
- Online Replacement: ON/OFF switch with isolated AC/DC connectors.
- Current Limit: Limits maximum output power to 1200W.
- Parallel Operation: Output diode supports connecting multiple units.
- Hold-Up Time: 100ms typical at full load for stability.
- Under-Voltage Alarm: Relay de-energizes below 54V DC.
- Protection: Against continuous overload and short-circuit.
Technical Specifications
- Model: Honeywell FC-PSU-UNI6020U.
- Output: 60V DC, 20A at -5°C to +50°C.
- Derating: 30W/°C above 50°C up to 70°C.
- Ripple & Noise: <75 mVpp clean output.
- Efficiency: >85% at 220-240V AC, >80% at 110-120V AC.
- Approvals: CE, TUV, UL508, CSA certified.
- Weight: 5.7 kg (12.5 lb) with cable set.
Input Specifications
- Voltage Range: 93-253V AC operational (110-240V AC nominal).
- Frequency: 47-63 Hz.
- Input Current: <7.5A at 220-240V AC, <16A at 110-120V AC.
- Inrush Current: <15A.
- Input Power: <1400 VA at 220-240V, <1500 VA at 110-120V.
- No Load Consumption: 13W typical.
- Power Factor: Close to unity.
Output Specifications
- Output Voltage: 60V DC fixed setting.
- Output Current: 0-20A continuous up to 50°C.
- Power Limit: 1200W maximum with current limit.
- Hold-Up Time: 100ms typical at 100% load.
- Voltage Limit: Independent regulation circuits for safety.
Alarm & Monitoring
- Under-Voltage Alarm: Relay de-energizes below 54V DC.
- Alarm Contact: 3-pole Phoenix socket type MC 1,5/3-G-3,81.
- Mating Connector: Phoenix MC 1,5/3-ST-3,81 included.
- DC Under-Voltage: Visual or system alert capability.
Connectors
- AC Input: IEC 60320 C20 inlet, 16A with retaining clip.
- DC Output: Phoenix PCV4/3-G-7,62 with locking screws.
- DC Cable: Phoenix PC 5/3-STF-7,62 mating connector.
- Isolated Connectors: Enable safe online replacement.
Isolation Ratings
- Input to Output: 3750 Vrms isolation.
- Input to Case: 2500 Vrms isolation.
- Output to Case: 1500 V DC isolation.
Physical Dimensions
- Width: 420.5 mm (16.6 in).
- Height: 140 mm (5.5 in).
- Depth: 90 mm (3.5 in).
- Weight: 5.7 kg (12.5 lb) including cable set.
Environmental Ratings
- Operating Temp: -5°C to +70°C (23°F to +158°F).
- Storage Temp: -25°C to +85°C (-13°F to +185°F).
- Derating: Starts at 50°C, 30W/°C reduction.
FAQ
-
Q: Can I connect multiple FC-PSU-UNI6020U units in parallel?
A: Yes. Built-in output diode supports parallel operation for higher current or redundancy. This enables system expansion without additional components. -
Q: What causes the under-voltage alarm to trigger?
A: Alarm relay de-energizes when output drops below 54V DC. This provides early warning of input power issues or overload conditions. -
Q: What is the derating requirement above 50°C?
A: Output current reduces by 30W per °C above 50°C. At 60°C, maximum output is approximately 900W (15A). Plan installations accordingly for hot environments.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can PLC and ERP Integration Drive Paperless Production?
This article explores how integrating Programmable Logic Controllers (PLC) with Enterprise Resource Planning (ERP) sy...
-
How Do PLC and DCS Survive Extreme Temperatures?
This article explores strategies for maintaining PLC and DCS reliability in high-temperature and high-pressure indu...
-
How PLC and DCS Optimize Pharmaceutical Manufacturing
This article examines how Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS) form the founda...
-
How Do PLC and DCS Transform Modern Warehouse Automation?
This article explores how programmable logic controllers (PLCs) and distributed control systems (DCS) work together t...
-
How Do PLC and DCS Improve Coal-Fired Power Plant Automation?
This article examines the evolving role of PLC and DCS technologies in modern coal-fired power plants. It covers hybr...
-
Which Automation Strategies Deliver the Best Energy Savings?
Intelligent control systems are transforming industrial energy management through demand-responsive scheduling, seque...