Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:FC-PSU-UNI4825U
Honeywell FC-PSU-UNI4825U 48V 25A Power Supply
Manufacturer: Honeywell
Product No.: FC-PSU-UNI4825U
Product Type: Power Supply Unit
Product Origin: USA
Payment:T/T, Western Union
Weight: 5700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
48V 25A Industrial Power Supply
Honeywell FC-PSU-UNI4825U delivers 48V DC at 25A for industrial applications. This UL508 approved supply provides stable power for demanding systems.
Key Features
- Dual OVP: Meets DIN V 19250 and VDE V 0801 safety standards.
- Online Replacement: ON/OFF switch with isolated AC/DC connectors.
- Current Limit: Limits maximum output power to 1200W.
- Parallel Operation: Output diode supports connecting multiple units.
- Hold-Up Time: 100ms typical at full load for stability.
- Under-Voltage Alarm: Relay de-energizes below 44V DC.
- Protection: Against continuous overload and short-circuit.
Technical Specifications
- Model: Honeywell FC-PSU-UNI4825U.
- Output: 48V DC, 25A at -5°C to +50°C.
- Derating: 30W/°C above 50°C up to 70°C.
- Ripple & Noise: <75 mVpp clean output.
- Efficiency: >85% at 220-240V AC, >80% at 110-120V AC.
- Approvals: CE, TUV, UL508, CSA certified.
- Weight: 5.7 kg (12.5 lb) with cable set.
Input Specifications
- Voltage Range: 93-253V AC operational (110-240V AC nominal).
- Frequency: 47-63 Hz.
- Input Current: <7.5A at 220-240V AC, <16A at 110-120V AC.
- Inrush Current: <15A.
- Input Power: <1400 VA at 220-240V, <1500 VA at 110-120V.
- No Load Consumption: 13W typical.
- Power Factor: Close to unity.
Output Specifications
- Output Voltage: 48V DC fixed setting.
- Output Current: 0-25A continuous up to 50°C.
- Power Limit: 1200W maximum with current limit.
- Hold-Up Time: 100ms typical at 100% load.
- Voltage Limit: Independent regulation circuits for safety.
Alarm & Monitoring
- Under-Voltage Alarm: Relay de-energizes below 44V DC.
- Alarm Contact: 3-pole Phoenix socket type MC 1,5/3-G-3,81.
- Mating Connector: Phoenix MC 1,5/3-ST-3,81 included.
- DC Under-Voltage: Visual or system alert capability.
Isolation Ratings
- Input to Output: 3750 Vrms isolation.
- Input to Case: 2500 Vrms isolation.
- Output to Case: 1500 V DC isolation.
Physical Dimensions
- Width: 420.5 mm (16.6 in).
- Height: 140 mm (5.5 in).
- Depth: 90 mm (3.5 in).
- Weight: 5.7 kg (12.5 lb) including cable set.
Environmental Ratings
- Operating Temp: -5°C to +70°C (23°F to +158°F).
- Storage Temp: -25°C to +85°C (-13°F to +185°F).
- Derating: Starts at 50°C, 30W/°C reduction.
FAQ
-
Q: Can I connect multiple FC-PSU-UNI4825U units in parallel?
A: Yes. Built-in output diode supports parallel operation for higher current or redundancy. This enables system expansion without additional components. -
Q: What causes the under-voltage alarm to trigger?
A: Alarm relay de-energizes when output drops below 44V DC. This provides early warning of input power issues or overload conditions. -
Q: What is the derating requirement above 50°C?
A: Output current reduces by 30W per °C above 50°C. At 60°C, maximum output is approximately 900W (18.75A). Plan installations accordingly for hot environments.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
-
How Does ABB Omni-Measurement Eliminate Process Safety Blind Spots?
ABB Omni-Measurement closes process safety blind spots using predictive analytics and cross-validated sensing. Real r...