Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:DC-TAOX11
Honeywell DC-TAOX11 System Module | 24V Output
Manufacturer: Honeywell
Product No.: DC-TAOX11
Product Type: Analog Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
DC-TAOX11 is a Honeywell System Module serving as an input system module. It delivers up to 24V maximum output compliant voltage. This module supports analog signal acquisition for Experion PKS.
Technical Specifications
| Manufacturer | Honeywell |
| Product Number | DC-TAOX11 |
| Product Type | System Module / Input System Module |
| Maximum Output Compliant Voltage | 24 VDC |
| Input Channels | 8 analog inputs |
| Input Signal Range | 0 to 20 mA / 4 to 20 mA / ±10 VDC |
| Resolution | 16 bits |
| Accuracy | ±0.05% of span (25°C) |
| Sampling Rate | 20 ms per channel |
| Power Supply | 24 VDC ±10% |
| Current Consumption | 150 mA |
| Heat Dissipation | 3.6 Watts |
| Isolation | 1500 Vrms (channel to backplane) |
| Operating Temperature | -40°F to 185°F (-40°C to +85°C) |
| Storage Temperature | -40°F to 185°F (-40°C to +85°C) |
| Mounting | DIN rail |
Installation Guide
Mount the module on DIN rail with proper grounding. Connect shielded twisted pair cables for analog inputs. Terminate the shield at the module end only. Verify 24 VDC power polarity before energizing the system.
Engineering Advantages
The DC-TAOX11 delivers 16-bit resolution for precise analog measurement. 1500 Vrms isolation protects the backplane from field transients. This module operates reliably from -40°F to 185°F, suitable for extreme environments.
FAQs
Q1: Can this module accept both current and voltage inputs?
A1: Yes. Each channel configures independently for 0-20 mA, 4-20 mA, or ±10 VDC.
Q2: What is the maximum input voltage without damage?
A2: The module withstands ±30 VDC on any analog input channel.
Q3: Does the DC-TAOX11 support HART communication?
A3: No. This is an analog input module only. Use a separate HART multiplexer for digital overlay.
Additional Specifications
- Gray
- Black
- Silver
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...