Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:900A16-0101
Honeywell 900A16-0101 Analog Input Module Voltage Current
Manufacturer: Honeywell
Product No.: 900A16-0101
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell 900A16-0101 High-Level Analog Input Module
The Honeywell 900A16-0101 is a high-level analog input module. It offers 16 configurable input channels. This module provides reliable signal acquisition for industrial process control systems.
Technical Specifications
- Brand Honeywell
- Model 900A16-0101
- Product Weight 0.8 kg
- Series High-Level Analog Input Module
- Number of Inputs 16
- Input Types Voltage or Current (user-configurable)
- Isolation Type Point-to-point and back-plane isolation
- LED Indicators Green (scanning), Amber (forced), Red (fault)
- Calibration Field calibration support available
- Failsafe User-selectable value per channel
- Shunt Resistor Integrated 250-ohm per input (DIP switch control)
- Terminal Block Requires Euro style 36-terminal block
Key Features
- 16-Channel Input 16 configurable voltage/current channels
- Dual Isolation Point-to-point and back-plane for safety
- Visual Diagnostics Multi-color LED status indicators
- Field Calibration Supports on-site calibration adjustments
- Integrated Shunt 250-ohm resistor for current loop conversion
- Flexible Failsafe Programmable failsafe value per input
- Robust Weight Solid 0.8 kg construction
Installation
- Install in compatible Honeywell I/O rack
- Configure input type per channel via software
- Set DIP switches for shunt resistor activation
- Connect signals to 36-terminal Euro style block
- Monitor LED indicators for module status
- Perform field calibration as needed
Packaging
- One 900A16-0101 Analog Input Module
- Shipping weight: 1.2 kg
- Shipped via FedEx UPS DHL
FAQ
How many input channels does this module have?
The 900A16-0101 has 16 configurable analog input channels.
What is the module's weight?
It weighs 0.8 kg.
What types of signals can it accept?
It accepts either voltage or current signals, configurable per channel by the user.
Additional Specifications
- Gray
- Green
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...