Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200ALG260C
GE Versamax IC200ALG260C 0-10V Differential Input Module
Manufacturer: General Electric
Product No.: IC200ALG260C
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The IC200ALG260C is a high-performance Analog Input Module from the GE Fanuc Versamax controller line. This module interfaces external industrial instrumentation with the central PLC architecture, accepting voltage or current signals such as 0-10 VDC and 4-20 mA loop inputs. Supporting both single-ended and differential terminal configurations, it delivers stable data conversion with high common-mode noise rejection across challenging factory environments.
Core Features
- Versatile Signaling: Configurable to read standard 0-10 VDC voltage loops or 4-20 mA process current loops.
- Dual Topology Modes: Supports single-ended wiring for high channel density or differential wiring for high-noise areas.
- High Galvanic Isolation: Provides 1500 VAC insulation protection to isolate delicate backplane logic from field electrical faults.
- Precision Conversion: Delivers high-accuracy telemetry with an exceptional ±0.1% Full Scale rating.
Technical Specifications
| Parameter | Data |
|---|---|
| Model Number | IC200ALG260C |
| Input Channel Topologies | Differential or Single-ended Input |
| Input Signal Ranges | 0 to 10 VDC (Voltage) / 4 to 20 mA (Current) |
| Conversion Accuracy | ±0.1% Full Scale |
| Module Net Weight | 0.3 kg (0.66 lbs) |
| Electrical Isolation | 1500 VAC isolation safety barrier |
| Current Consumption | 200 mA at 24 VDC external/backplane link |
| Physical Dimensions | 84 mm × 95 mm × 45 mm (3.31 × 3.74 × 1.77 in) |
| Operating Constraints | −20°C to +60°C / 5% to 95% RH (Non-condensing) |
| Compliance Certifications | CE, UL, CSA Approved |
Engineering & Installation Guide
- Wiring Configuration Rule: Select differential wiring mode when input transmitters are located far away or run through high-EMI conduits. Use single-ended wiring only if all sources share an identical, local ground potential.
- Thermal Management: Keep a standard 50 mm convective cooling space above and below the module carrier to ensure stable internal temperatures within its −20°C to +60°C rating.
- Vibration and Housing Support: Securely snap the 0.3 kg module block onto its terminal carrier base. Ensure the DIN rail clips are locked to counter constant industrial vibrations that can loose wiring contacts.
Technical FAQs
Q1: How do I choose between single-ended and differential wiring on the IC200ALG260 module?
A1: Input type configuration is managed during terminal block field installation and software parameter configuration. Differential mode uses two leads per channel to reject ground loops, while single-ended mode ties the negative return paths together, maximizing your usable input density.
Q2: Why is the 1500 VAC isolation rating critical for this analog input card?
A2: Industrial environments are highly vulnerable to high-voltage lightning surges, inductive motor kickbacks, and ground fault spikes. The 1500 VAC galvanic isolation barrier stops severe field-side electrical faults from leaping across to damage your expensive central Versamax CPU.
Q3: Does this module require external power or runs entirely on backplane power?
A3: The module draws up to 24 VDC power (consuming 200 mA) to drive its internal analog-to-digital conversion circuits and reference loops. Always calculate your complete backplane power budget before mounting multiple heavy analog cards side-by-side.
Additional Specifications
- Black
- Gray
- DC-powered
- Compact
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...