Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IS200ECTBG2A
GE IS200ECTBG2A Exciter Contact Terminal Board EX2100
Manufacturer: General Electric
Product No.: IS200ECTBG2A
Product Type: Terminal Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE IS200ECTBG2A Exciter Contact Terminal Board
The GE IS200ECTBG2A is an Exciter Contact Terminal Board (ECTB) from the EX2100 Excitation Control System. Designed for simplex mode operation, it provides trip contact outputs, general-purpose Form-C relay outputs, and auxiliary contact inputs for excitation control applications.
Product Identification
- Manufacturer: General Electric (GE Industrial Systems)
- Part Number: IS200ECTBG2A
- Series: EX2100
- Functional Acronym: ECTB
- Board Version: ECTBG2
- Operational Mode: Simplex Mode only
- Country of Origin: United States
- Manual: GEI-100457A / GEH-6632
Technical Specifications
| Parameter | Value |
|---|---|
| Relay Break Characteristic | 28V DC |
| Relay Control Voltage | 24V DC |
| Customer Power | 125V DC |
| Wetting Voltage | 70V DC (63-84V range) |
| Dimensions (W×H×D) | 150 × 76 × 90 mm |
| Weight | 0.34 kg (3lbs 4oz) |
Functional Description
The ECTB board supports excitation contact outputs and contact inputs for the EX2100 excitation control system. It contains two trip contact outputs for customer lockout drivers and four general-purpose Form-C relay contact outputs controlled by the EMIO board. Six auxiliary contact inputs are wetted with 70V DC, and the 52G and 86G contact inputs are also powered and monitored.
Relay Control and Feedback
| Relay Type | Description |
|---|---|
| Trip Relay Outputs | K1M1, K2M1 driven by EMIO in M1. Two parallel normally closed contacts per lockout. |
| General Purpose Relays | K1GP, K2GP, K3GP, K4GP. Form-C type with NO, NC, common terminals. |
Contact Inputs
- Six customer-supplied auxiliary contact inputs powered and monitored using 70V DC.
- 52G contact input monitored with 70V DC excitation.
- 86G contact input wetted with 70V DC.
- Red LED indicates contact state for each input.
- Inputs fanned to M1, M2, and C controllers (M1 only in simplex).
Connectors and Interface
- J405, J408, J415: 25-pin sub-D connectors for cables to EBKP backplane (EMIO boards M1, M2, C).
- J13M1, J13M2: Plugs bringing 70V DC for contact wetting from M1 and M2 power supplies.
- TB1, TB2: Removable terminal blocks held with two screws.
Installation
- Board is used in simplex mode only (G2 version).
- Managed by EMIO board which collects inputs/outputs and sends logic level gate pulse signals over backplane to ESEL board.
- Verify 24V DC relay control voltage from M1 controller.
- Customer power should be 125V DC nominal.
- Wetting voltage range: 63-84V DC from EPSM module.
Technical FAQs
Q1: What is the difference between ECTBG2A and ECTBG1?
A1: ECTBG2A is used in simplex mode only, while ECTBG1 is used in redundant mode.
Q2: What relays are controlled by the EMIO board?
A2: Two trip relays (K1M1, K2M1) and four general-purpose relays (K1GP-K4GP).
Q3: What is the wetting voltage for contact inputs?
A3: 70V DC nominal, with a range of 63-84V DC.
Additional Specifications
- Green
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can GE Fanuc PLC + Emerson DCS Cut Your Plant Upgrade Costs?
This article examines a data-proven retrofit strategy combining GE Fanuc PLC and Emerson DeltaV DCS for legacy indust...
-
Why Bently Nevada Bridges Process Control and Machine Health?
Unobserved mechanical vibration remains a critical blind spot in modern factory automation, causing up to 8% annual r...
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...