Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC660BBA020
GE Genius I/O IC660BBA020 Analog Module 4 Input 2 Output
Manufacturer: General Electric
Product No.: IC660BBA020
Product Type: Combination I/O Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1800g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Genius I/O Analog I/O Module IC660BBA020
The GE Genius I/O IC660BBA020 is an analog input/output module for Genius network systems. It provides 4 analog inputs and 2 analog outputs with 12-bit resolution for precise process control applications.
Technical Specifications
- Brand & Model: GE Genius I/O IC660BBA020
- Module Type: Analog Input/Output Module
- Analog Inputs: 4 channels
- Input Signals: 0-10V DC, ±10V DC, ±5V DC, 0-5V DC, 4-20 mA
- Analog Outputs: 2 channels
- Output Signals: 0-10V DC, 0-5V DC, 4-20 mA (configurable)
- Resolution: 12-bit + sign
- Accuracy: ±0.2% typical, ±0.5% maximum of full scale
- Power Supply: 18-56 VDC (24/48 VDC block power)
- Protocol: Genius Protocol
- Isolation: 1500V block-to-block
- Heat Dissipation: 6 Watts
- Dimensions (H×W×D): 22.44 × 8.89 × 10.00 cm (8.83" × 3.50" × 3.94")
- Product Weight: 1.8 kg (4 lbs)
- Status Indicators: Unit OK, I/O Enabled LEDs
Key Features
- 4 high-precision analog input channels
- 2 configurable analog output channels
- 12-bit + sign resolution for accurate signal processing
- Wide input voltage range (18-56 VDC)
- Genius Protocol for reliable industrial communication
- 1500V isolation for safety and noise immunity
- Status LEDs for easy monitoring
Shipping Information
- 1x IC660BBA020 analog I/O module
- Approximate shipping weight: 2.2 kg (including packaging)
- Secure protective packaging
- Shipped via FedEx, UPS, or DHL
FAQ
-
What analog signals can it handle?
Inputs: 0-10V, ±10V, ±5V, 0-5V, 4-20mA. Outputs: 0-10V, 0-5V, 4-20mA. -
What is the Genius Protocol?
A high-speed serial communication protocol developed by GE for industrial I/O systems. -
What is the module's resolution?
12-bit plus sign bit, providing high precision for analog signal conversion.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Is 99.8% Reliability Critical for Your PLC and DCS Systems?
This article explains why rigorously vetted cross-border control parts stabilize industrial automation operations. It...
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...