Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC755CKS06RDMEP
GE Fanuc IC755CKS06RDMEP Modbus TCP 24V 0.625A
Manufacturer: General Electric
Product No.: IC755CKS06RDMEP
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC755CKS06RDMEP Quickpanel+ Operator Terminal
GE Fanuc IC755CKS06RDMEP is a Quickpanel+ terminal with RSTi-ED Modbus TCP. Features 6-inch TFT LCD touchscreen, ARM Cortex A8 1GHz processor, 512MB DRAM, and Windows Embedded Compact 7 OS.
Key Specifications
| Parameter | Value |
|---|---|
| Part Number | IC755CKS06RDMEP |
| Type | Quickpanel+ with RSTi-ED Modbus TCP |
| Display Size | 6 inches (5.7 inch active area) |
| Display Technology | TFT LCD with resistive touchscreen |
| Processor | ARM Cortex A8, 1GHz |
| Operating System | Windows Embedded Compact 7 (32-bit) |
| DRAM | 512 MB |
| Input Voltage | 24V DC |
| Current Input | 0.625A (15W max) |
| Weight | 0.7 kg |
Dimensions
| Parameter | Value |
|---|---|
| Width x Height x Depth | 192 x 137 x 36 mm |
| Panel Cutout | 183.5 x 128.5 mm |
Mounting & Installation
- Panel mount with cutout: 183.5 x 128.5 mm
- Clamp screw torque: 0.3 N·m
- VESA MIS-D compatible (arm/stand mount)
- Back mounting holes: M4 screws (6mm or less)
- VESA screw torque: 0.7-0.8 N·m
Communication Interfaces
- Ethernet port for network connectivity
- USB ports for peripherals
- Serial interface for legacy devices
- Protocol: RSTi-ED Modbus TCP
Features
- 1 tri-color LED for visual status updates
- Firmware upgrade via SD card
- GUI stored in flash, executed from DRAM
- UL1678 compliant for mounting apparatus
Environmental Limits
| Parameter | Value |
|---|---|
| Operating Temperature | 32°F to 131°F (0°C to 55°C) |
FAQs
Q1: What is the display size and type?
A1: 6-inch TFT LCD with resistive touchscreen (5.7 inch active area).
Q2: What processor and OS does this terminal use?
A2: ARM Cortex A8 at 1GHz with Windows Embedded Compact 7.
Q3: What is the power requirement?
A3: 24V DC at 0.625A (15W max).
Additional Specifications
- Clear
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...
