Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC755ACC15GAS
GE Fanuc IC755ACC15GAS Replacement Gasket 15 Inch Quickpanel
Manufacturer: General Electric
Product No.: IC755ACC15GAS
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1360g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC755ACC15GAS is a replacement gasket for 15‑inch Quickpanel industrial touchscreen terminals. Quickpanel units ship with pre‑installed gaskets that can be field‑replaced if damaged. This gasket ensures IP65 enclosure protection, safeguarding the unit from dust and water ingress. Weight: 1.36 kg (3.00 lbs).
Core Advantages
IP65 Enclosure Protection
Provides dust‑tight and water‑jet resistant sealing when installed in a metal enclosure. Maintains the integrity of your Quickpanel terminal in harsh industrial environments.
Field‑Replaceable Design
Easy to replace in the field without special tools. GE Fanuc recommends using a fresh gasket for full protection after removal.
Precision Fit for 15‑Inch Models
Designed exclusively for 15‑inch Quickpanel units. Ensures proper compression and sealing around the display bezel.
Specifications
| Parameter | Value |
|---|---|
| Part Number | IC755ACC15GAS |
| Manufacturer | GE Fanuc / Emerson |
| Type | Replacement Gasket |
| Compatibility | 15‑inch Quickpanel Units |
| Enclosure Material | Metal (recommended) |
| Protection Rating | IP65 |
| Input Voltage | 12/24 Vdc (±20%) |
| Power Consumption | 30 W max |
| Current @ 12Vdc | 2.5 A |
| Current @ 24Vdc | 1.25 A |
| Panel Cutout (15‑inch unit) | 14.92 × 12.01 inches |
| VESA Mount | 3.94 × 3.94 inches |
| Compliance | EU RoHS 2011/65/EU |
| Weight | 1.36 kg (3.00 lbs) |
Installation Tips
Enclosure Requirements
Install in a metal enclosure rated IP65. Avoid repeated removal and re‑insertion of the Quickpanel unit as this may damage the gasket seal.
Gasket Replacement
When replacing a damaged gasket, clean the sealing surface thoroughly before installing the new IC755ACC15GAS. Ensure even compression across all edges.
Mounting Options
For 15‑inch units, use panel cutout 14.92 × 12.01 inches or VESA mount 3.94 × 3.94 inches.
Environmental Precautions
Install in well‑ventilated locations away from rain, dust, corrosive gases, and direct sunlight.
Why Choose IC755ACC15GAS?
Genuine GE Fanuc replacement gasket ensures proper IP65 sealing for 15‑inch Quickpanel units. Precision‑molded for exact fit. Prevents dust and moisture ingress that can damage sensitive touchscreen and internal electronics. Lightweight at 1.36 kg. Easy field replacement minimises downtime.
FAQs
Q1: Can I reuse the old gasket after removing the Quickpanel unit?
A1: GE Fanuc does not recommend repeated removal and insertion. Use a fresh IC755ACC15GAS gasket for full IP65 protection after removal.
Q2: What enclosure material is required for IP65 protection?
A2: A metal enclosure is required for proper sealing with the IC755ACC15GAS gasket.
Q3: Is this gasket compatible with other Quickpanel screen sizes?
A3: No. The IC755ACC15GAS is specifically designed for 15‑inch Quickpanel units only.
Additional Specifications
- Clear
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Replace Honeywell 5130 DCS I/O Modules Safely?
This article reviews Honeywell 5130 series DCS I/O module specifications, aging failure modes, firmware compatibility...
-
How Does GE Proficy iFIX SCADA Improve Factory Automation?
This article explains practical GE Proficy iFIX SCADA deployment, covering hardware sizing, SCU node setup, graphic s...
-
How Does Siemens ET200SP Simplify PLC and DCS Integration?
This article explains Siemens ET200SP distributed remote I/O hardware sizing, DIN rail installation, field wirin...
-
How Do GE IC695 RX3i I/O Modules Work?
This article explains GE IC695 RX3i I/O module specifications, compatibility validation, field installation proc...
-
What Is Emerson DeltaV Virtual DCS and How Does It Work?
Emerson DeltaV Virtual DCS replicates full distributed control system behavior using identical runtime binaries, enab...
-
How to Commission Siemens PCS 7 OS for DCS Plants?
This article explains how to commission, troubleshoot and tune Siemens PCS 7 OS operator stations for distribute...
