Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC697ALG320
GE Fanuc IC697ALG320 4-Channel Analog Output Module Series 90-70
Manufacturer: General Electric
Product No.: IC697ALG320
Product Type: Analog Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 850g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC697ALG320 Analog Output Module
GE Fanuc IC697ALG320 is a 4-channel analog output module for Series 90-70 PLC architecture. Each channel configures independently for voltage (±10V) or current (4-20mA) signals. Features software-driven jumperless design, onboard EEPROM calibration, and 0.85kg compact form factor.
Technical Specifications
| Parameter | Specification |
| Manufacturer | GE Fanuc / Emerson Automation |
| Model | IC697ALG320 |
| Platform | Series 90-70 |
| Output Channels | 4 individually configurable |
| Voltage Ranges | 0 to +10V unipolar, -10V to +10V bipolar |
| Current Range | 0 to 22.5 mA (4-20 mA optimized) |
| Calibration | Onboard EEPROM non-volatile memory |
| Default Output Behavior | Hold last value or force to off state |
| Diagnostics | LED status indicators, software alerts |
| Weight | 0.85 kg (1.87 lbs) |
Core Technical Advantages
Software-Driven Jumperless Architecture
No manual hardware jumpers or DIP switches. All configuration assignments are defined entirely through programming software, simplifying field commissioning and eliminating manual setup errors.
Integrated Non-Volatile Memory Calibration
Each channel undergoes factory calibration with constants stored directly in onboard EEPROM. The module references this data during runtime to ensure accurate tracking and protection against signal drift.
Flexible Range and Signal Profiling
Every channel supports mixed signal types within a single module slot. Advanced digital scaling maps raw engineering values directly to physical outputs.
Installation Guidelines
Backplane Insertion: Power off the Series 90-70 rack before installation. Align the circuit card edge with chassis slot guides and lock mechanical latches.
Field Wiring: Maintain separation between low-voltage analog paths and high-voltage AC lines. Ground cable shields at a single point to minimize EMI interference.
Software Configuration: Define signal format, scaling points, and safety fallback preferences for each channel through the PLC configuration utility.
FAQs
Q1. Can I mix voltage and current signals across different channels?
A1. Yes. Each of the 4 channels operates independently. You can configure Channel 1 for 4-20 mA and Channel 2 for ±10V simultaneously without cross-channel interference.
Q2. How does jumperless configuration simplify field replacement?
A2. No physical switches to mirror. Simply remove the failed module and insert a replacement. The CPU automatically pushes the software configuration to the new card upon boot-up, minimizing downtime.
Q3. What happens to outputs when CPU communication fails?
A3. You configure the fallback behavior. Each channel can be set to either hold its last valid output value or force to an off state during a CPU fault condition.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
-
Can Remote Maintenance Reduce Factory Automation Costs?
Manufacturing plants lose millions to traditional on-site PLC maintenance. This article presents a field-verified thr...
-
Can Emergency Imported Spares Stop Unplanned Factory Downtime?
Unplanned control system failures cost industrial facilities up to $500,000 per hour, yet OEM lead times stretch from...