Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693CHS392E
GE Fanuc IC693CHS392E Series 90-30 PLC Expansion Baseplate
Manufacturer: General Electric
Product No.: IC693CHS392E
Product Type: I/O Expansion Baseplate
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693CHS392E is a 10-slot expansion baseplate engineered for the Series 90-30 PLC system. Designed to extend system I/O capacity beyond the main CPU baseplate, it allows up to 10 discrete, analog, or option modules to be mounted in a single rack. The IC693CHS392E requires a Series 90-30 Power Supply unit installed in its left-most slot to deliver power across the backplane and connects to the primary CPU rack or preceding expansion rack via a standard I/O bus expansion cable. Weighing approximately 1.0 kg (2.2 lbs), this panel-mount baseplate ensures long-term industrial durability and seamless modular scalability.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | IC693CHS392E |
| PLC Family | GE Fanuc Series 90-30 |
| Baseplate Type | Expansion Baseplate (Local / Remote I/O) |
| Number of I/O Slots | 10 Slots (Slots 1 through 10) |
| Power Supply Requirement | Requires 1x Series 90-30 Power Supply (e.g., PWR321 / PWR330) |
| Backplane Current Draw | 150 mA @ 5 VDC (baseplate logic consumption) |
| Bus Connection Ports | 2x 25-Pin D-sub Expansion Bus Connectors (In / Out) |
| Mounting Method | Direct Panel Mount / Enclosure Backplane Mount |
| Physical Dimensions | 443 x 130 x 142 mm (17.44 x 5.12 x 5.59 in) |
| Net Weight | 1.0 kg (2.2 lbs) |
Key Design & Hardware Features
- 10-Slot High-Density Capacity: Maximizes rack density by offering 10 full-featured slots for I/O modules, motion control modules, and communication interfaces.
- Dual Expansion Bus Connectors: Equipped with female 25-pin expansion bus ports (IN and OUT) to allow daisy-chaining multiple expansion racks up to maximum system cable limits.
- Dedicated Power Supply Position: Features a left-hand dedicated power supply slot to generate backplane 5 VDC and 24 VDC relay power for installed modules.
- Industrial Panel Installation: Rugged metal backing plate ensures mechanical rigidity and proper ground connection when secured to control panel sub-panels.
Installation & Engineering Guidelines
1. Rack Addressing: Set the rack DIP switch on the IC693CHS392E baseplate to assign a unique rack address (Rack 1 through 7) so the CPU can correctly address all installed I/O points.
2. Bus Termination: If the IC693CHS392E is the final expansion rack in the daisy chain, attach a bus terminator plug (IC690ACC901) to the OUT expansion connector to prevent bus signal reflection.
3. Power Supply Selection: Ensure the power supply module inserted into the expansion baseplate can provide sufficient 5 VDC current to meet the cumulative power consumption of all 10 module slots.
Frequently Asked Questions (FAQs)
Q1: Can a CPU module (e.g., IC693CPU370) be installed directly into the IC693CHS392E baseplate?
A1: No. The IC693CHS392E is an expansion baseplate. CPU modules can only be installed in slot 1 of a Main Baseplate (such as the IC693CHS391).
Q2: How many IC693CHS392E expansion racks can be connected to a single Series 90-30 CPU system?
A2: Depending on the specific CPU model used, a Series 90-30 system supports up to 7 expansion baseplates daisy-chained together using expansion cables.
Q3: Does the IC693CHS392E expansion rack require its own separate power supply module?
A3: Yes. Each expansion rack requires a dedicated Series 90-30 Power Supply unit installed in the left-most power slot to supply power to the local backplane.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Choose Between ABB DCS and AB PLC for Your Plant?
This guide delivers data-backed rules for selecting ABB DCS or Allen-Bradley PLC based on process characteristic...
-
How Did This Refinery Cut Unplanned Downtime by 42% in 8 Months?
Unplanned downtime costs refineries up to $8,581 per minute, largely due to siloed PLC and DCS systems. This expert a...
-
Can GE Fanuc PLC + Emerson DCS Cut Your Plant Upgrade Costs?
This article examines a data-proven retrofit strategy combining GE Fanuc PLC and Emerson DeltaV DCS for legacy indust...
-
Why Bently Nevada Bridges Process Control and Machine Health?
Unobserved mechanical vibration remains a critical blind spot in modern factory automation, causing up to 8% annual r...
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
