Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200CBL520
GE Fanuc IC200CBL520 RS-485 Cable DataPanel Series 90
Manufacturer: General Electric
Product No.: IC200CBL520
Product Type: Communication Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC200CBL520 DataPanel RS-485 Communication Cable
GE Fanuc IC200CBL520 is a Series 90 SNP 15-pin RS-485 cable designed for DataPanel 20/40/60 connectivity. Enables communication between DataPanel operator interfaces and GE Fanuc Series 90 PLC systems. Weight: 0.5 kg (1.10 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | GE Fanuc |
| Model | IC200CBL520 |
| Product Type | Communication Cable |
| Protocol | SNP (Series 90 Native Protocol) |
| Communication Interface | RS-485 |
| Connector Type | 15-pin (DataPanel end) |
| Compatible DataPanels | DataPanel 20, 40, 60 |
| Weight | 0.5 kg (1.10 lbs) |
Key Features
- Direct connection between DataPanel 20/40/60 and Series 90 PLC systems
- SNP protocol support for seamless communication
- RS-485 interface for reliable data transfer
- 15-pin connector for DataPanel interface
- Ready-to-use cable for easy installation
Installation Guidelines (Field Engineer Notes)
Connection: Connect the 15-pin end to the DataPanel. Connect the other end to the Series 90 PLC SNP port. Ensure proper alignment before tightening.
Cable Routing: Maintain 50mm separation from power cables. Avoid sharp bends. Minimum bend radius is 50mm.
Communication Check: Verify PLC and DataPanel are configured for SNP protocol. Baud rate settings must match on both devices.
FAQs
Q1. What DataPanel models are compatible with this cable?
A1. The IC200CBL520 is compatible with DataPanel 20, DataPanel 40, and DataPanel 60 operator interfaces.
Q2. What protocol does this cable support?
A2. The cable supports SNP (Series 90 Native Protocol) for communication between DataPanel and Series 90 PLC systems.
Q3. Is this cable compatible with other GE PLC series?
A3. The cable is designed for Series 90 PLC systems with SNP protocol support. Other series may require different cables or adapters.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Do Default Bently Nevada Thresholds Trigger 71.8% Nuisance Alarms?
This technical article examines why factory-default Bently Nevada 3500 vibration thresholds frequently fail in real-w...
-
How to Optimize Spare Parts Sourcing for Honeywell Gas Detection?
This article presents a structured approach to sourcing Honeywell gas detection spares for industrial automation syst...
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
