Skip to content
Automation parts, worldwide supply
Skip to product information
1 of 3

SKU:IC200ALG262

GE Fanuc IC200ALG262 8-Channel Analog Current Module

Only 10 units left
  • Manufacturer: General Electric

  • Product No.: IC200ALG262

  • Product Type: Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 130g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The IC200ALG262 is a high-precision 15-Bit Differential Analog Current Input Module from the GE VersaMax PLC series. This module features 8 isolated differential input channels designed to interface with industrial current transmitters, such as flow meters, pressure sensors, and temperature links. By providing superior noise rejection across balanced signal lines, it delivers stable, high-resolution telemetry data directly to the core automation controller.

Core Features

  • 15-Bit High Resolution: Provides extreme measurement sensitivity down to 0.5 µA for precise process loop control.
  • Isolated Differential Inputs: Features 8 differential channels that reject common-mode noise and eliminate ground loop interference.
  • Smart Diagnostics: Offers active loss-of-field-side power monitoring and open-wire fault detection.
  • Flexible Current Ranges: Supports standard industrial signal matching via hardware jumper selection.

Technical Specifications

Parameter Data
Model Number IC200ALG262
Input Configurations 8 Isolated Differential Channels
Selectable Current Ranges 4 to 20 mA or 0 to 20 mA (Jumper Selectable)
Measurement Resolution 15 bits (0.5 µA for 4–20 mA / 0.625 µA for 0–20 mA)
Module Net Weight Approx. 0.13 kg (4.6 oz)
Channel Update Rate 7.5 milliseconds per channel
Input Impedance / CMRR 100 Ω / 70 dB typical Common Mode Rejection Ratio
Common Mode Range −10V to +10V
Internal Power Draw 200 mA maximum from the +5V PLC backplane
Status Indicators Green "OK" LED confirms backplane power and active module health

Engineering & Installation Guide

  • Shielded Wiring Standards: Always route analog input signals using high-quality Shielded Twisted Pair (STP) cable to block electromagnetic interference (EMI).
  • Proper Shield Grounding: Terminate cable shields at the signal source end. If the source is ungrounded, connect the shield drain wire to the VersaMax I/O auxiliary terminal strip.
  • Open Wire Detection Limits: Note that open-wire fault monitoring only functions when the channel jumper is explicitly configured for the 4 to 20 mA operational range.
  • Weight and Vibration Support: At a lightweight 0.13 kg, ensure the module snaps firmly into its carrier base to avoid contact oxidation during industrial machine vibrations.

Technical FAQs

Q1: How do I switch between 0–20 mA and 4–20 mA current input ranges on the IC200ALG262?
A1: The current range configuration is managed via physical wiring jumpers on the terminal carrier block. Adding or removing specific channel jumper links scales the internal 15-bit analog-to-digital converter to match the desired instrument output span.

Q2: What happens if field-side loop power drops during operation?
A2: The module instantly triggers a "loss of field-side power" diagnostic flag. This system alert reports up through the VersaMax CPU PLC hardware diagnostics table while the onboard "OK" LED provides visual status confirmation of backplane health.

Q3: Why are differential inputs preferred over single-ended inputs for current loops?
A3: Differential inputs look at the voltage difference between two separate signal lines rather than measuring against system ground. This approach successfully cancels out common-mode noise and cross-talk voltages, which is vital when routing analog wires over long industrial distances.

🏷️ Tags: Analog Input Module

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.