Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC200ALG262
GE Fanuc IC200ALG262 8-Channel Analog Current Module
Manufacturer: General Electric
Product No.: IC200ALG262
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 130g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The IC200ALG262 is a high-precision 15-Bit Differential Analog Current Input Module from the GE VersaMax PLC series. This module features 8 isolated differential input channels designed to interface with industrial current transmitters, such as flow meters, pressure sensors, and temperature links. By providing superior noise rejection across balanced signal lines, it delivers stable, high-resolution telemetry data directly to the core automation controller.
Core Features
- 15-Bit High Resolution: Provides extreme measurement sensitivity down to 0.5 µA for precise process loop control.
- Isolated Differential Inputs: Features 8 differential channels that reject common-mode noise and eliminate ground loop interference.
- Smart Diagnostics: Offers active loss-of-field-side power monitoring and open-wire fault detection.
- Flexible Current Ranges: Supports standard industrial signal matching via hardware jumper selection.
Technical Specifications
| Parameter | Data |
|---|---|
| Model Number | IC200ALG262 |
| Input Configurations | 8 Isolated Differential Channels |
| Selectable Current Ranges | 4 to 20 mA or 0 to 20 mA (Jumper Selectable) |
| Measurement Resolution | 15 bits (0.5 µA for 4–20 mA / 0.625 µA for 0–20 mA) |
| Module Net Weight | Approx. 0.13 kg (4.6 oz) |
| Channel Update Rate | 7.5 milliseconds per channel |
| Input Impedance / CMRR | 100 Ω / 70 dB typical Common Mode Rejection Ratio |
| Common Mode Range | −10V to +10V |
| Internal Power Draw | 200 mA maximum from the +5V PLC backplane |
| Status Indicators | Green "OK" LED confirms backplane power and active module health |
Engineering & Installation Guide
- Shielded Wiring Standards: Always route analog input signals using high-quality Shielded Twisted Pair (STP) cable to block electromagnetic interference (EMI).
- Proper Shield Grounding: Terminate cable shields at the signal source end. If the source is ungrounded, connect the shield drain wire to the VersaMax I/O auxiliary terminal strip.
- Open Wire Detection Limits: Note that open-wire fault monitoring only functions when the channel jumper is explicitly configured for the 4 to 20 mA operational range.
- Weight and Vibration Support: At a lightweight 0.13 kg, ensure the module snaps firmly into its carrier base to avoid contact oxidation during industrial machine vibrations.
Technical FAQs
Q1: How do I switch between 0–20 mA and 4–20 mA current input ranges on the IC200ALG262?
A1: The current range configuration is managed via physical wiring jumpers on the terminal carrier block. Adding or removing specific channel jumper links scales the internal 15-bit analog-to-digital converter to match the desired instrument output span.
Q2: What happens if field-side loop power drops during operation?
A2: The module instantly triggers a "loss of field-side power" diagnostic flag. This system alert reports up through the VersaMax CPU PLC hardware diagnostics table while the onboard "OK" LED provides visual status confirmation of backplane health.
Q3: Why are differential inputs preferred over single-ended inputs for current loops?
A3: Differential inputs look at the voltage difference between two separate signal lines rather than measuring against system ground. This approach successfully cancels out common-mode noise and cross-talk voltages, which is vital when routing analog wires over long industrial distances.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...