Skip to content
Automation parts, worldwide supply
Skip to product information
1 of 3

SKU:IC693MDL241

GE 90-30 PLC 24V Discrete Input Module IC693MDL241

In stock (21 units), ready to be shipped
  • Manufacturer: General Electric

  • Product No.: IC693MDL241

  • Product Type: Discrete Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 340g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Technical Specifications

Part Number IC693MDL241
Product Type Discrete Input Module (AC / DC)
Brand / Manufacturer GE Fanuc / GE Intelligent Platforms
Product Series Series 90-30 PLC
Number of Inputs 16 Channels (Single isolated group with one common terminal)
Wiring Configuration Positive / Negative Logic (Sinking/Sourcing for DC mode)
Nominal Input Voltage 24 V AC / 24 V DC (50/60 Hz frequency for AC)
Input Voltage Range 0 to +30 V AC or 0 to +30 V DC
On-State Voltage / Current 11.5 to 30.0 V AC/DC / 3.2 mA minimum
Off-State Voltage / Current 0 to 4.0 V AC/DC / 1 mA maximum
Input Current Draw 7 mA per channel typical at rated nominal voltage
Backplane Power Draw 80 mA @ 5 V DC (All inputs ON); 125 mA from isolated 24 V DC bus
Signal Response Times Typical ON response: 12 ms / Maximum OFF response: 28 ms
Galvanic Isolation 1500 V RMS / 1500 V AC between field side and logic side
Net Product Weight 0.34 kg (Approx. 0.75 lbs)

Product Overview

The IC693MDL241 is a highly versatile 16-channel Discrete Input Module belonging to the globally deployed GE Fanuc Series 90-30 Programmable Logic Controller (PLC) architecture. Weighing a manageable 0.34 kg (0.75 lbs), this module provides exceptional deployment flexibility by processing either 24V AC or 24V DC field input signals within a single hardware block. Thanks to its smart dual-logic input design, it interfaces natively with positive or negative logic topologies (sinking or sourcing configurations) to safely monitor critical binary components including pushbuttons, electronic proximity switches, limit switches, and auxiliary relay contacts.

Core Technical Advantages

  • Flexible Multi-Voltage Compatibility: Accepts an extended operational range of 0 to 30 Volts in both alternating current (AC) and direct current (DC) configurations, reducing the necessity for separate module inventories.
  • Flexible Sinking and Sourcing Logic: Adapts directly to diverse user-supplied wiring logic topologies, matching positive or negative industrial control circuitry effortlessly in DC configurations.
  • High Galvanic Voltage Isolation: Integrates a strict 1500 V RMS optical separation path between the raw electrical field side and the sensitive internal CPU computing backplane, neutralizing noise spikes.
  • Detailed Real-Time Status Matrix: Incorporates two horizontal rows of eight sharp green LED indicators (labeled A1–A8 and B1–B8) to deliver clear visual diagnostics when active 7 mA field signals write a Logic 1 (%I) state to the CPU registry.

Installation Guide

De-energize the main power supply feeding the destination 5-slot or 10-slot Series 90-30 chassis prior to board insertion. Carefully align the rear connectors of the 0.34 kg IC693MDL241 along the upper and lower plastic channel tracks, pressing smoothly until the hardware security clips snap shut into the chassis rail. Route your 24V field circuits into the module's terminal block, connecting the common line appropriately to establish the preferred sinking or sourcing structure. The external loop can be powered directly via the PLC backplane's isolated 24V DC terminal or driven cleanly by an auxiliary external power supply array.

Technical FAQs

Q1: What are the exact voltage levels needed to guarantee an ON or OFF input state?
A1: To reliably trigger an active ON state (Logic 1), the field input must supply between 11.5 and 30.0 V AC/DC. Any residual signal dropped between 0 and 4.0 V AC/DC is read as an absolute OFF state (Logic 0).

Q2: Why does the documentation show two distinct 24V current draw figures?
A2: The module consumes 80 mA from the internal 5 V DC backplane to power its logic components when all points are active. The secondary 125 mA draw is pulled from the isolated 24 V DC bus (or an external field supply) to operate the optical isolation loops and input channel circuitry.

Q3: Does the 0.34 kg weight of this card require any additional reinforcement during vertical mounting?
A3: No. The light 0.34 kg physical footprint is securely held by the standard built-in slot hooks of the Series 90-30 baseplate framework, maintaining heavy vibration dampening in standard control panel environments.

🏷️ Tags: Discrete Input Module

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.