Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:369B1844G0019
GE 369B1844G0019 | Analog Input Unit 4-20mA -10-10V
Manufacturer: General Electric
Product No.: 369B1844G0019
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE 369B1844G0019 Digital Output Card
Product Overview
The GE 369B1844G0019 is a digital output card designed for industrial control systems. It functions as an analog input (AI) unit that converts continuous analog signals from sensors (temperature, pressure, speed, flow, displacement) into digital signals for PLC processing. The module supports standard analog input levels including -10 to +10V, 0 to 10V, 1 to 5V voltage signals and 4 to 20mA current signals. Weight is 0.35 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | GE Nexus |
| Model | 369B1844G0019 |
| Product Type | Digital Output Card / Analog Input Unit |
| Input Voltage Signal Range | -10 to +10V, 0 to 10V, 1 to 5V |
| Input Current Signal Range | 4 to 20 mA |
| Signal Processing | A/D Conversion with Optical Isolation |
| Interface Type | I/O Expansion Interface |
| Key Components | Signal Processing, Multiplexer, A/D Converter, Optocoupler Isolation |
| Weight | 0.35 kg |
Key Features
- Converts analog sensor signals to digital data for PLC processing
- Supports voltage inputs: -10 to +10V, 0 to 10V, 1 to 5V
- Supports current inputs: 4 to 20mA
- Integrated signal processing and multiplexing
- A/D converter for high-precision digital conversion
- Optocoupler isolation for signal integrity and protection
- I/O expansion interface for system scalability
- Compatible with GE XDPS-400e control system
Functional Description
The 369B1844G0019 analog input unit captures continuous analog signals from industrial sensors measuring temperature, pressure, speed, flow, and displacement. These signals are processed through signal conditioning, multiplexed via a multi-channel switch, converted to digital format by the A/D converter, and isolated through optocouplers before being transmitted to the CPU. The I/O expansion interface allows connection to additional I/O units when system point counts exceed the main PLC capacity.
Installation Notes
Install the module in the designated slot of the XDPS-400e rack. Ensure proper wiring for voltage or current inputs based on sensor output type. For current signals, ensure loop power is supplied externally. Use shielded cables for analog signals to minimize noise interference. Configure input range settings via system software prior to operation.
FAQs
Q1: What types of input signals does this module accept?
A1: Voltage signals: -10 to +10V, 0 to 10V, 1 to 5V. Current signals: 4 to 20mA.
Q2: What is the purpose of the I/O expansion interface?
A2: It allows connection of additional I/O expansion units when the system requires more input/output points than the main PLC provides.
Q3: What isolation method is used on this module?
A3: Optocoupler isolation is used to protect the CPU and maintain signal integrity between field devices and the control system.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can ABB’s Signal Linkage Cut Downtime 60%?
This article examines how ABB’s multi-layer industrial communication architecture resolves cross-equipment signal mis...
-
Is Your Gas Detection Transmitter Costing You Millions?
Fixed calibration schedules waste millions and hide critical risks. This article presents a data-driven, risk-tiered ...
-
Is Your PLC and DCS Logic Hiding Energy Savings?
This article presents a three-layer framework for industrial energy optimization using ABB automation technology. It ...
-
How Can Real-Time Data Governance Prevent Unplanned Downtime?
Uncalibrated sensors and inconsistent tag naming are causing a trillion-dollar "data debt" in process manufacturing. ...
-
Can Programmable Interlock Eliminate 31% of Assembly Downtime?
This engineering guide examines programmable interlock logic for assembly lines using Allen‑Bradley control platforms...
-
How ABB's Risk Platform Cuts Industrial Plant Downtime?
ABB's intelligent risk identification platform addresses unresolved safety gaps in conventional control-system operat...
