  • Manufacturer: Honeywell

  • Product No.: FC-IOTA-NR24

  • Product Type: Termination Assembly

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 310g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The FC-IOTA-NR24 is a compact, non-redundant Input/Output Termination Assembly (IOTA) engineered for high-integrity safety applications. Certified for use in safety instrumented functions up to SIL 3 compliance (IEC 61508/61511), this module serves as the rugged field wiring interface for Honeywell Safety Manager systems. It bridges field instrumentation directly to processing logic by hosting critical safety modules, guaranteeing extreme precision and fail-safe operation in hazardous environments like chemical plants and refineries.

Core Technical Advantages

  • High-Density Universal I/O: Provides 32 flexible software-configurable channels, minimizing physical footprint and hardware overhead.
  • SIL 3 Safety Compliance: Engineered to meet strict IEC 61508 standards for Emergency Shutdown (ESD) and safety-critical control.
  • Robust Power Infrastructure: Features integrated reverse-polarity protection and a heavy-duty 15A fuse to safeguard internal circuitry.
  • Dual Network Continuity: Equipped with dual RJ45 ports for deterministic 100MB Ethernet communication across control networks.

Technical Specifications

Parameter Specification Details
Model Number FC-IOTA-NR24
Module Compatibility Supports 1x RUSIO-3224 or RUSLS-3224 module
I/O Capacity 32 Universal I/O Channels (CN1, CN2) + 4 V+ Connections (CN3)
Supported I/O Types Digital Input, ESD Input, Analog Input/Output, Digital Output
Power Supply 24V DC (-15% to +30%), Max. 10A load
Circuit Protection Parallel Diode (Reverse Polarity), Littelfuse 15A Blade Fuse
Network Interface 2x RJ45 Connectors (100MB Ethernet via RIOLA / RIOLB)
Operating Conditions -40°C to +70°C; 10% to 95% RH (Non-condensing)
Dimensions (H x W x D) 64 x 120.7 x 293.4 mm
Approvals CE, UL, TUV, Pollution Degree 2

Installation & Maintenance Guide

Wiring and Connections

Secure the 24V DC input wires to the dedicated 24V and COM screws on the carrier power rails. Connect active Analog Input (AI) field devices to the four identical V+ power distribution points labeled CN3, and route general field signals to headers CN1 and CN2.

Environmental and Mounting Guidelines

Mount the assembly horizontally or vertically inside a Pollution Degree 2 (or better) rated enclosure to prevent dust buildup. Ensure ambient temperatures remain between -40°C and +70°C to prevent thermal stress or drift in critical channels.

Fuse Replacement Safeties

If a power surge trips the circuit protection, always isolate power before servicing. Replace only with an identical 15A, 32V DC automotive blade fuse (Manufacturer Part Number: Littelfuse 0287015.PXS) to maintain certified safety tolerances.

Engineering Advantages

  • Universal Flexibility: Eliminates the need to buy separate analog and digital modules, allowing mixed loop configurations on a single board.
  • Extreme Resilience: Operates reliably from -40°C up to +70°C, matching the demands of remote instrument enclosures without auxiliary cooling.
  • Fail-Safe Communication: Dual RJ45 ports (RIOLA/RIOLB) support dual-path network data routing to prevent safety loop disconnects.

Technical FAQs

Q1: What types of I/O modules can be installed on the FC-IOTA-NR24?
A1: The assembly accommodates exactly one RUSIO-3224 or one RUSLS-3224 module, providing full software-configurable control over mixed signal types.

Q2: Can this termination assembly be used in redundant configurations?
A2: No. The FC-IOTA-NR24 is strictly a non-redundant (NR) assembly. For high-availability redundant architectures, a dedicated redundant-type IOTA baseboard must be selected.

Q3: What is the purpose of the CN3 connections on this assembly?
A3: The CN3 interface supplies four independent, filtered V+ power loops specifically designed to drive active 2-wire or 3-wire analog field transmitters.

🏷️ Tags: Termination Assembly
  • Green
  • DC-powered
  • Compact
  • Modular

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.