Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD616VP43AFTHA
Delta VFD616VP43AFTHA 61kW 115A VFD Drive
Manufacturer: Delta
Product No.: VFD616VP43AFTHA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 10000g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
61kW Heavy-Duty Variable Frequency Drive
Delta VFD616VP43AFTHA delivers 61kW for high-power industrial motors. This VFD operates on 380-480V three-phase power. It handles large compressors, extruders, and heavy fans with stable performance.
Power & Current Ratings
- Rated Power: 61 kW (82 HP).
- Output Current (ND): 115A.
- Output Current (HD): 91A.
- Input Current: 104A at 380V, 92A at 480V.
- Overload (ND): 120% for 60s.
- Overload (HD): 150% for 3s.
Input & Output Specs
- Input Voltage: 380-480V AC ±10%, 3-phase.
- Input Frequency: 47-63 Hz.
- Output Frequency: 0 to 400 Hz.
- Frequency Resolution: 0.01 Hz.
- Carrier Frequency: 2-15 kHz adjustable.
- Power Factor: >0.95 at rated load.
Control Performance
- Starting Torque: 150% at 0.5Hz.
- Speed Range: 1:100 open loop.
- Speed Accuracy: ±0.5% open loop.
- Accel/Decel Time: 0.1-3600s.
- Torque Response: <50ms.
Protection Functions
- Over-current: 200% trip threshold.
- Over-voltage: Shutdown at 820V DC bus.
- Under-voltage: Trip below 350V DC bus.
- Over-temp: Heatsink >85°C protection.
- Phase Loss: Input and output detection.
- Short Circuit: Instantaneous trip.
Environmental Ratings
- Operating Temp: -10°C to 50°C.
- Storage Temp: -20°C to 60°C.
- Humidity: 5-95% non-condensing.
- Altitude: 1000m without derating.
- Protection: IP20.
Dimensions & Weight
- Width: 320 mm (12.6 in).
- Height: 550 mm (21.65 in).
- Depth: 275 mm (10.83 in).
- Weight: 10 kg
Package & Shipping
- Includes: One Delta VFD616VP43AFTHA drive.
- Delivery: FedEx, UPS, DHL.
- Status: In stock.
- Payment: T/T, Western Union.
FAQ
-
Q: What is the maximum cable length?
A: Shielded cable max 100m. Unshielded max 200m. Add output reactor beyond these lengths. -
Q: Does it have a built-in braking chopper?
A: Yes. Use external resistor (min 15 ohms, 15kW) for dynamic braking. -
Q: What communication options are available?
A: Standard RS-485 Modbus RTU. Optional cards for Profibus, EtherNet/IP, DeviceNet, CANopen.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...