Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CMC-EC01
Delta CMC-EC01 EtherCAT Communication Card | 2-Port
Manufacturer: Delta
Product No.: CMC-EC01
Product Type: Communication Card
Product Origin: CN
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Delta CMC-EC01 EtherCAT Communication Card
The Delta CMC-EC01 is a high-performance EtherCAT communication card. It enables fast industrial network connectivity for Delta automation systems and servo drives.
Core Specifications
- Brand & Model: Delta CMC-EC01
- Product Type: EtherCAT Communication Card
- Number of Ports: 2 independent EtherCAT ports
- Transmission Standard: IEEE 802.3, IEEE 802.3u compliant
- Cable Type: Category 5e shielded, 100 meter maximum
- Transmission Speed: 10/100 Mbps auto-negotiation
Communication Features
- Communication Protocol: EtherCAT (Ethernet for Control Automation Technology)
- Network Topology: Supports line, star, and tree topologies
- Synchronization: High-precision distributed clock function
- Application: PLC networks, multi-axis motion control, distributed I/O systems
Physical Specifications
- Card Weight: Approximately 0.15 kg (0.33 lbs)
- Compact Design: Standard card format for Delta controllers
- Connector Type: Standard RJ45 Ethernet ports
- Mounting: Designed for slot installation in compatible Delta units
Package Contents & Shipping
- One CMC-EC01 EtherCAT communication card
- Package Weight: 0.3 kg (0.66 lbs) including packaging
- Installation guide and documentation
- Mounting screws (if required)
- Shipping: Available via FedEx, UPS, DHL
Installation Guide
- Power off the main controller before installation
- Insert card into appropriate communication slot
- Secure with provided mounting screws if necessary
- Connect Category 5e shielded Ethernet cables to both ports
- Configure network settings in Delta programming software
- Verify communication status through system diagnostics
FAQ
What devices is this card compatible with?
Compatible with Delta PLCs, motion controllers, and drives supporting EtherCAT.
What cable should I use for best performance?
Use shielded Category 5e Ethernet cables for reliable industrial communication.
Can I daisy-chain multiple devices?
Yes, EtherCAT supports daisy-chain topology for efficient network design.
Additional Specifications
- Black
- Gray
- Green
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
