Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-PAOH51
CC-PAOH51 Honeywell HART Analog Output Experion PKS
Manufacturer: Honeywell
Product No.: CC-PAOH51
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Key features & benefits
- 16 HART-enabled analog output channels for precise 4-20mA control.
- Integrated HART modems enable remote diagnostics and device configuration.
- ±0.1% accuracy with 16-bit resolution for critical loop control.
- Supports redundant configuration with <10ms switchover.
- G3 conformal coating option (-176) protects against corrosive environments.
Technical specifications
- Brand & model: Honeywell CC-PAOH51 (51410070-175/176/275)
- Type: HART Analog Output Module
- Output channels: 16
- Output signal: 4-20mA (0-20mA, 0-10V selectable)
- Resolution: 16-bit
- Accuracy: ±0.1% of full scale
- Linearity: ±0.05% of full scale
- Maximum resistive load: 800 ohms at 24V supply
- Output ripple: <100mV peak-to-peak
- Response time: <80ms settle to 1%
- Power supply: 24V DC (18-30V DC)
- Power consumption: 4W max
- Isolation: 500V channel-to-channel, 1500V channel-to-system
- Operating temperature: 0 to +60°C
- Storage temperature: -40 to +85°C
- Humidity: 5-95% non-condensing
- Weight: 0.35kg
- Certifications: CE, UL, CSA, Class I Div 2 / Zone 2
Installation guide
- Mount CC-PAOH51 onto Series C I/O rack with compatible IOTA (CC-TAOX51 non-redundant or CC-TAOX61 redundant).
- Connect field wiring to termination assembly.
- Configure FAILOPT options: Hold Last Value, Shed Low (4mA), or Shed High (20mA).
- For redundant setups, install dual modules with <10ms switchover.
- Module supports hot-swap in redundant configuration.
FAQ
-
What is CC-PAOH51?
16-channel HART analog output module for Experion PKS Series C. Provides 4-20mA control with integrated HART diagnostics. Weight 0.35kg. -
Difference between -175 and -176 suffix?
-176 includes G3 conformal coating for protection against corrosive gases like H₂S. -175 is standard coating. -
Is external HART multiplexer required?
No. HART modems are integrated into each channel. Digital data passes through Series C I/O link.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Zero-Downtime PLC Migration: Upgrade Without Stopping?
Aging GE Fanuc PLCs pose significant operational risks due to part shortages and failing IoT compatibility. This arti...
-
Why Integrate Bently Nevada Vibration Monitoring with Emerson AMS?
This technical article examines how integrating Emerson AMS asset management software with Bently Nevada vibration se...
-
How Reliable Are Your Control System Components Against Counterfeits?
This article presents a data-driven approach to verifying genuine Emerson DCS modules for Industry 4.0 projects. It q...
-
Why Integrate TSI with PLC for Gas Compressor Stations?
This technical article examines the integration of Bently Nevada 3500 TSI systems with GE Fanuc PLC platforms for int...
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
What Are the Root Causes of Intermittent TSI Communication Errors?
This article delivers a quantitative troubleshooting methodology for GE Fanuc PLC and Bently Nevada TSI communication...
