Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CC-KFPVR5
CC-KFPVR5 51202353-111 Honeywell 16-Ch Analog Input
Manufacturer: Honeywell
Product No.: CC-KFPVR5
Product Type: Analog I/O Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The CC-KFPVR5 51202353-111 is a 16-channel analog input module from Honeywell, designed for high-level analog signal acquisition with HART communication. It accepts 0–10 V, ±10 V, or 4–20 mA inputs with 16-bit resolution and ±0.1% accuracy. Built for extreme environments, it operates from -40°C to 70°C. Weight: 2.0 kg.
Technical Configuration
16-Channel Analog Input with HART
16 single-ended inputs supporting voltage (0–10 V / ±10 V) and current (4–20 mA) signals. HART communication enables digital data overlay on analog loops for diagnostics and configuration. 1500 VDC channel-to-bus isolation ensures signal integrity.
High-Speed Scanning
250 ms update rate per channel delivers fast, accurate data acquisition. 16-bit resolution and ±0.1% accuracy provide precise measurement for critical process control.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | CC-KFPVR5 51202353-111 |
| Manufacturer | Honeywell |
| Channel Count | 16 single-ended inputs |
| Input Type | High-level analog with HART |
| Voltage Range | 0–10 V or ±10 V |
| Current Range | 4–20 mA |
| Resolution | 16-bit |
| Accuracy | ±0.1% of full scale |
| Input Impedance | >1 MΩ (voltage) / 250 Ω (current) |
| Update Rate | 250 ms per channel |
| Operating Temperature | -40°C to 70°C |
| Power Supply | 24 VDC nominal |
| Isolation | 1500 VDC channel-to-bus |
| Dimensions (L x W x H) | 12.1 cm x 2.5 cm x 11.2 cm |
| Weight | 0.5 kg |
| Warranty | 12 months |
Installation & Maintenance
Wiring
Connect voltage or current signals to the 16 single-ended inputs. For current loops, ensure 250 Ω load impedance. Use shielded twisted-pair cables to minimize noise. HART communication requires a compatible hand-held or host system.
Configuration
Configure input range (voltage/current) and HART parameters via Honeywell DCS or configuration software. The module supports digital HART data extraction for device diagnostics and process variable monitoring.
Maintenance
1500 VDC isolation protects against ground loops and transients. Regular inspection of connections and LED status indicators ensures reliable operation. 12-month warranty provides coverage for manufacturing defects.
Engineering Advantages
Extreme Temperature Operation
Wide operating range of -40°C to 70°C enables deployment in outdoor, unheated, and process-intensive environments. Suitable for oil, gas, and chemical applications.
HART Communication
Integrated HART capability allows digital access to field device diagnostics, calibration data, and secondary variables without additional wiring. Reduces maintenance costs and improves process insight.
High Accuracy & Speed
±0.1% accuracy with 16-bit resolution ensures precise measurement. 250 ms update rate per channel supports fast control loops and real-time monitoring.
Technical FAQs
Q1: What input types does this module support?
A1: Voltage (0–10 V or ±10 V) and current (4–20 mA). Input impedance is >1 MΩ for voltage and 250 Ω for current.
Q2: Does this module support HART communication?
A2: Yes. Each channel supports HART digital communication overlay on analog signals, enabling device diagnostics and configuration.
Q3: What is the isolation rating?
A3: 1500 VDC channel-to-bus isolation, protecting against ground loops and electrical transients.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Programmable Interlock Eliminate 31% of Assembly Downtime?
This engineering guide examines programmable interlock logic for assembly lines using Allen‑Bradley control platforms...
-
How ABB's Risk Platform Cuts Industrial Plant Downtime?
ABB's intelligent risk identification platform addresses unresolved safety gaps in conventional control-system operat...
-
Can Automation Lifecycle Services Mitigate PLC and DCS Obsolescence?
This article examines how industrial facilities mitigate obsolescence risk in PLC, DCS, TSI and power-protection syst...
-
Can Rugged PLC Hardware Cut Downtime by 41% in Steel Mills?
Field surveys across metallurgy and petrochemical sites confirm that thermal stress drives 68% of random control-syst...
-
Can a Unified Platform Cut Hidden Downtime by 40%?
Fragmented PLC, DCS, and TSI systems in power and chemical plants create data silos that cause 68% of unplanned downt...
-
Can Unified DCS Reduce Power Plant Downtime by 38%?
This article examines the measurable operational and financial outcomes of deploying GE Vernova Mark VIe distributed ...
