Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:3500/33-01-01
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Manufacturer: Bently Nevada
Product No.: 3500/33-01-01
Product Type: Relay Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Bently Nevada 3500/33-01-01 3500/33 16-Channel Relay Output Module. Provides 16 independent SPDT relay outputs for machinery protection systems. Epoxy-sealed relays with arc suppressors ensure reliable operation in demanding industrial environments. cNRTLus certified for Class I Division 2 hazardous areas.
Key Features
16 SPDT relay outputs. Epoxy-sealed environmental sealing. 250 Vrms arc suppressor standard. Four groups of four channels with switch-selectable Normally De-energized (ND) or Normally Energized (NE) operation. Front panel OK, TX/RX, and CH Alarm LEDs. 5.8W typical power consumption. Main module 0.7 kg, I/O module 0.4 kg.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 3500/33-01-01 |
| Product Type | 3500/33 16-Channel Relay Module |
| Output Module (A) | 01 = 16-Channel Relay Output |
| Approval Option (B) | 01 = cNRTLus (Class I Division 2) |
| Power Consumption | 5.8 W typical |
| Relay Type | Single-pole Double-throw (SPDT) |
| Environmental Sealing | Epoxy-sealed |
| Arc Suppressor | 250 Vrms (standard) |
| Relay Contact Life | 10,000 cycles |
| Relay Operation | 4 groups of 4, switch-selectable ND/NE |
| Main Module Dimensions | 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in) |
| Main Module Weight | 0.7 kg (1.6 lb) |
| I/O Module Dimensions | 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in) |
| I/O Module Weight | 0.4 kg (1.0 lb) |
| Rack Space (Main) | 1 full-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Origin | Made in U.S.A. |
Contact Ratings
Standard Relays
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage (DC) | 125 Vdc |
| Max Switched Voltage (AC) | 250 Vac |
| Max Switched Power (DC) | 70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc |
| Max Switched Power (AC) | 1200 VA |
Failsafe / Hazardous Area Systems
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage | 30 Vdc |
Low Current Applications
| Min Switched Current | 1 mA @ 1 Vdc |
| Max Switched Current | 100 mA @ 48 Vdc |
Ordering Code Breakdown
3500/33-01-01
3500/33 – 16-Channel Relay Module.
A:01 – 16-Channel Relay Output Module.
B:01 – cNRTLus (Class I Division 2) hazardous area approval.
Installation Notes
Install main module in full-height front slot. Install I/O module in corresponding rear slot. Configure relay groups for ND or NE operation via switches. Observe contact rating limits for standard, failsafe, or low current applications. Ensure proper grounding per Bently Nevada guidelines.
Engineering Advantages
16 independent relay outputs provide flexible alarm and control signaling. Epoxy-sealed relays withstand harsh industrial environments. Arc suppressors extend contact life and reduce EMI. cNRTLus certification enables installation in Class I Division 2 hazardous areas. Switch-selectable ND/NE per group simplifies integration with existing control schemes.
FAQs
Q1: How many relay outputs does this module provide?
A1: 16 independent SPDT relay outputs.
Q2: What are the contact ratings for standard applications?
A2: 5A max, 125Vdc or 250Vac, 70W @ 24Vdc.
Q3: What is the relay operation configuration?
A3: Four groups of four channels, switch-selectable for Normally De-energized or Normally Energized operation.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...