Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-ACNR15
Allen-Bradley FLEX IO 1794-ACNR15 5 Mbps Network Module
Manufacturer: Allen-Bradley
Product No.: 1794-ACNR15
Product Type: Adapter Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 210g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 1794-ACNR15 is a high-reliability, Redundant ControlNet Adapter Module from Allen-Bradley's dependable FLEX IO product line. Serving as an intelligent network interface component, this lightweight 0.21 kg module bridges distributed factory-floor I/O modules directly to a master Programmable Logic Controller (PLC) over a deterministic ControlNet network link. Featuring dual physical BNC ports, it maintains uninterrupted communication tokens across a redundant media loop, ensuring continuous uptime for critical process lines and heavy industrial machinery.
Core Features
- Redundant Media Interface: Equipped with two ControlNet BNC ports to provide active communication path protection against single-point cable failures.
- High Backplane Capacity: Delivers a maximum of 640 mA of Flexbus output current to seamlessly power high-density local discrete or analog I/O racks.
- Superior Galvanic Isolation: Features a high 850V DC electrical isolation barrier to shield sensitive backplane logic components from field surges.
- Excellent Noise Immunity: Built-in 60 dB noise rejection combined with 100 dB common mode rejection ensures reliable data transfers in high EMI environments.
Technical Specifications
| Parameter | Data |
|---|---|
| Model / Catalog Number | 1794-ACNR15 (FLEX IO Architecture) |
| Network Interface Profile | Redundant ControlNet Media Adapter |
| Physical Connections | 2 x ControlNet BNC Coaxial Ports (Channel A and Channel B) |
| Data Transfer Rate | 5 Mbps (Deterministic clock speed) |
| External Power Requirement | 24V DC nominal (19.2 to 31.2V DC allowable window) |
| Current / Power Consumption | 400 mA max from external supply / 3.4W max power dissipation @ 19.2V |
| Inrush Current Rating | 23 Amps for a 2 millisecond startup window |
| Max Flexbus Output Current | 640 mA maximum logic supply link |
| System Precision Performance | ±0.1% full-scale accuracy tracking with a 10 ms quick response time |
| Module Net Weight | 0.21 kg (0.46 lbs) |
| Operating Ambient Range | −20 to 55 °C (−4 to 131 °F) extended thermal rating |
| Harmonized Tariff Code | 8537101190 |
Engineering & Installation Guide
- Mounting Support & Weight Limits: At a compact net weight of 0.21 kg, this adapter mounts easily onto a standard TS35 DIN rail. Ensure the rail configuration is free from heavy physical shock to protect the interconnected flex backplane lines from loose contacts.
- DIP Switch Station Addressing: Set the distinct ControlNet node address using the dual rotary or hardware DIP switches on the adapter module before snapping the unit onto the DIN rail framework.
- Dual Coaxial Network Tap Lines: Connect both standard RG-6 coaxial cables to ports A and B using the appropriate 1794 network taps. Keep a maximum wire cross-section of 3.31 mm² (12 AWG) in mind for auxiliary terminal interfaces.
- Inrush Current Mitigation: Ensure your source 24V DC line supply is adequately sized. The adapter triggers a sharp 23A inrush current spike for 2 ms during hot bootups, which can cause undersized fast-acting power supplies to trip out.
- Thermal Layout Space: Although this compact unit relies on passive convection cooling up to 55 °C, it generates 15.7 BTU/hr under full load. Ensure adequate ventilation gaps are maintained around your cabinet enclosure layout.
Technical FAQs
Q1: How does the redundant media protocol function across ports A and B on the 1794-ACNR15 module?
A1: The module processes incoming data tokens over both BNC channels simultaneously. If a physical break occurs on the primary trunk line (Channel A), the internal communication handler seamlessly uses the data stream from Channel B within microseconds, eliminating data dropouts or process stops.
Q2: Why is the 640 mA Flexbus output current threshold important when constructing an I/O rack?
A2: The 640 mA rating dictates the maximum logic current the adapter can feed to connected expansion modules down the backplane. Sum up the internal bus current requirements of all attached analog or discrete cards to ensure their total draw does not exceed this 640 mA maximum threshold.
Q3: What advantage do the 60 dB noise and 100 dB common mode rejection ratings provide in production fields?
A3: Heavy industrial machinery, such as large variable frequency drives (VFDs) and high-power welding apparatus, can generate severe electromagnetic field fluctuations. These specific rejection levels shield your real-time input telemetry data from corruption, ensuring it transfers back to the central controller with an accuracy profile of ±0.1%.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...