Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:2711P-RN3
Allen-Bradley 2711P-RN3 PanelView Plus DH-485 Comm Module
Manufacturer: Allen-Bradley
Product No.: 2711P-RN3
Product Type: Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 230g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 2711P-RN3 is a specialized DH-485 communication module designed for the PanelView Plus and PanelView Plus CE terminal series. This interface module allows your HMI to communicate seamlessly with SLC 500, MicroLogix, and other legacy controllers using the DH-485 protocol. With a lightweight and compact design weighing approximately 0.23 kg, this module is an essential upgrade for maintaining connectivity in traditional industrial networks.
Technical Specifications
| Feature | Specification |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Catalog Number | 2711P-RN3 |
| Protocol Supported | DH-485 |
| Interface Type | Serial (RS-485) |
| Comm Speed | Up to 19200 bps |
| Voltage Range | 24V DC |
| Typical Weight | 0.23 kg |
Installation and Compatibility
The 2711P-RN3 is compatible with the PanelView Plus 700, 1000, 1250, and 1500 terminals. Installation involves inserting the module into the internal communication slot located on the back of the logic module. Weighing just 0.23 kg, it does not add significant mechanical stress to the HMI assembly. Its non-condensing humidity rating of 5% to 95% ensures reliability in various industrial climates, from food processing to pharmaceutical manufacturing.
Operational Advantages
By using the 2711P-RN3, facility managers can extend the life of their existing SLC 500 control systems while upgrading to high-resolution PanelView Plus displays. The module’s 0.23 kg specialized housing protects the delicate serial circuitry, providing a long-term solution for machine-level communication. It remains one of the most trusted methods for integrating legacy DH-485 devices into a modern visualization architecture.
Technical FAQs
Q1: Does this module require separate configuration software?
A1: Configuration for the DH-485 protocol is typically handled through the FactoryTalk View ME software used to program the PanelView Plus terminal.
Q2: Can I use this for DH+ (Data Highway Plus) communication?
A2: No, the 2711P-RN3 is strictly for DH-485. For DH+ networks, the 2711P-RN6 module would be the appropriate choice.
Q3: Is the 0.23 kg weight consistent across different versions?
A3: Yes, the weight is standard for the internal communication module series. Total shipping weight will be approximately 0.45 kg due to protective packaging.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...