Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-OA8
Allen-Bradley 1794-OA8 Flex I/O AC Output Module
Manufacturer: Allen-Bradley
Product No.: 1794-OA8
Product Type: AC Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1794-OA8 Flex I/O AC Digital Output Module
Allen-Bradley 1794-OA8 | Flex I/O AC digital output module with 8 non-isolated output channels. Operates at 120V AC nominal voltage with 4.0 A output current rating. Designed for all non-hazardous industrial environments and Class 1, Division 2 areas. Weight: approximately 0.15 kg (0.33 lbs).
Key Features
8 non-isolated outputs in one group. 120V AC nominal output voltage, 85-132V AC range. 4.0 A output current rating. Minimum on-state current 5 mA per output. Maximum on-state voltage drop 1.0V at 0.5 A. Maximum off-state leakage 2.25 mA. 120V continuous isolation voltage. 80 mA Flexbus current at 5V DC. Surge current 7 A for 40 ms, repeatable every 8 seconds. Output signal delay max 1/2 cycle. Diagnostics for field devices, wiring, and power supply. Lightweight at 0.15 kg (0.33 lbs).
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OA8 |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 (Non-isolated) |
| Output Voltage (Nominal) | 120V AC |
| Output Voltage Range | 85-132V AC |
| Output Current Rating | 4.0 A |
| On-State Current (Min) | 5 mA per output |
| On-State Voltage Drop | 1.0V max @ 0.5 A |
| Off-State Leakage Current | 2.25 mA max |
| Isolation Voltage | 120V continuous |
| Flexbus Current | 80 mA @ 5V DC |
| Surge Current | 7 A for 40 ms, repeatable every 8 s |
| Signal Delay (ON/OFF) | Max 1/2 cycle |
| Power Dissipation | 4.1 W @ 0.5 A; 6.3 W @ 0.75 A and 1 A |
| Thermal Dissipation | 14.0 BTU/hr @ 0.5 A; 21.2 BTU/hr @ 0.75 A; 21.4 BTU/hr @ 1 A |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| UPC | 10612598137845 |
Current Derating by Temperature
| 55°C | 500 mA per output |
| 35°C | 750 mA per output |
| 30°C | 500 mA on 4 outputs; 1 A on 4 non-adjacent outputs |
Compatible Terminal Base Units
1794-TBNK, 1794-TBKD, 1794-TB3K, 1794-TBNFK, 1794-TB3SK, 1794-TBNF, 1794-TB3, 1794-TB2, 1794-TB3S, and 1794-TBN. Auxiliary terminal strips are required when using the 1794-TBN base unit.
Installation Notes
Install directly on compatible Flex I/O terminal base units. Use auxiliary terminal strips when mounting on the 1794-TBN base. Observe current derating based on ambient temperature: 500 mA per output at 55°C, 750 mA at 35°C. Verify off-state leakage does not affect connected loads. Ensure proper grounding per Allen-Bradley wiring guidelines. Suitable for non-hazardous and Class 1 Division 2 environments.
Engineering Advantages
Integrated diagnostics identify faults in field devices, wiring, and power supply, reducing commissioning and troubleshooting time. 8 outputs in a single Flex I/O module maximize channel density. High 4.0 A module rating handles demanding AC loads directly. Surge current capability of 7 A supports inductive load switching. Wide 85-132V AC range accommodates supply variations. Modular Flex I/O design enables flexible system expansion.
FAQs
Q1: How many outputs does this module provide?
A1: 8 non-isolated AC outputs in a single group.
Q2: What is the output voltage range?
A2: 85-132V AC, with a nominal rating of 120V AC.
Q3: What is the current rating at different temperatures?
A3: 500 mA per output at 55°C, 750 mA per output at 35°C, and 1 A on 4 non-adjacent outputs at 30°C.
Additional Specifications
- Gray
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
