Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-IT8
Allen-Bradley 1794-IT8 | Flex I/O Thermocouple Input 8-Ch
Manufacturer: Allen-Bradley
Product No.: 1794-IT8
Product Type: DC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1794-IT8 is an 8-channel Thermocouple/mV Analog Input Module for the Flex I/O system. It supports thermocouple types J, K, E, R, N, S, B, C, T, and L, plus ±76.5mV signals. With 16-bit resolution and 2.384 microvolt typical accuracy, it delivers precise temperature measurement in industrial applications.
Core Functionality
The 1794-IT8 interfaces directly with grounded or ungrounded thermocouples and millivolt transducers. It communicates with PLCs via block transfer programming, moving configuration words and input data between the module and the PLC data table. Two cold-junction compensators mount on the terminal base for accurate reference. The module requires key switch Position 3 on the terminal base for safe mounting.
Technical Specifications
| Parameter | Value |
| Part Number | 1794-IT8 |
| Series | Flex I/O |
| Module Type | Thermocouple/mV Input Module |
| Inputs | 8 channels |
| Thermocouple Types | J, K, E, R, N, S, B, C, T, L |
| Millivolt Range | ±76.5 mV |
| Resolution | 16-bit (2.384 µV typical) |
| Data Format | 16-bit 2's complement or offset binary |
| Isolation Voltage | 850V DC |
| Normal Mode Rejection | -60 dB at 60 Hz |
| Common Mode Rejection | -115 dB at 60 Hz / -100 dB at 50 Hz |
| Channel Bandwidth | 0 to 2.62 Hz |
| System Throughput | 325 ms |
| Flexbus Current | 20 mA |
| Power Dissipation | 3W max @ 31.2V |
| Thermal Dissipation | 10.2 BTU/hr @ 31.2V DC max |
| Terminal Base | 1794-TB2, -TB3, -TB3T |
| Keyswitch Position | 3 |
| CJC Unit Part Number | 969424-0 |
| Weight | Approx. 0.25 kg (0.55 lbs) |
Installation Guide
Rotate the terminal base keyswitch to Position 3 before inserting the 1794-IT8. Mount the two cold-junction compensators (969424-0) in their designated positions on the terminal base. Connect thermocouple or millivolt wiring, observing polarity for ±76.5mV inputs. Configure the module via block transfer programming in the PLC. Ensure 24V DC supply is connected. Supports both grounded and ungrounded thermocouples.
Engineering Advantages
This module supports 10 thermocouple types plus millivolt inputs for maximum application flexibility. 16-bit resolution with 2.384µV typical accuracy ensures precise temperature measurement. -115dB common mode rejection at 60Hz provides excellent noise immunity. 850V DC isolation protects the backplane. The dual cold-junction compensators maintain accurate reference compensation.
Technical FAQs
Q1: Supported thermocouple types and range?
A1: J, K, E, R, N, S, B, C, T, L plus ±76.5mV. Type B: 300-1800°C, Type K: -230 to 1372°C, Type J: -195 to 1200°C.
Q2: What terminal base and keyswitch position?
A2: Compatible with 1794-TB2, -TB3, -TB3T terminal bases. Keyswitch must be in Position 3 for safe mounting.
Q3: Resolution and isolation specs?
A3: 16-bit resolution (2.384µV typical). 850V DC isolation. Throughput 325ms. Flexbus current 20mA.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?