Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1794-IH16
Allen-Bradley 1794-IH16 Flex I/O Module 125VDC
Manufacturer: Allen-Bradley
Product No.: 1794-IH16
Product Type: DC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1794-IH16 Flex I/O Digital Input Module
Product Overview
Allen-Bradley 1794-IH16 is a digital input module for the Flex I/O 1794 series. Provides 16 input points at 125 V DC nominal voltage. Carries North American Hazardous Location approval. Inputs are non-isolated. Compatible with 1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK terminal bases. Module weight 0.3 kg.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Series | Flex I/O 1794 |
| Part Number | 1794-IH16 |
| Voltage Type | DC |
| Nominal Voltage | 125 V DC |
| Number of Inputs | 16 |
| Nominal Current | 2 mA |
| Minimum On-state Voltage | 90 V DC sinking |
| Maximum On-state Voltage | 146 V DC |
| Maximum Off-state Voltage | 20 V DC |
| On-state Input Current | 1 mA min, 2 mA nominal, 3 mA max |
| Maximum Off-state Current | 0.8 mA |
| Power Dissipation | 6 W at 146 V DC |
| Thermal Dissipation | 20.47 BTU/hr at 146 V DC |
| Dimensions Installed | 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) |
| Dimensions Uninstalled | 46 x 94 x 53 mm (1.8 x 3.7 x 2.1 in) |
| Weight | 0.3 kg |
Compatible Terminal Bases
- 1794-TB3
- 1794-TB3S
- 1794-TB3K
- 1794-TB3SK
Key Features
- 16 digital input points at 125 V DC nominal
- North American Hazardous Location approval rating
- Non-isolated inputs
- Minimum on-state voltage 90 V DC sinking
- Maximum on-state voltage 146 V DC
- Power dissipation 6 W at 146 V DC
FAQs
Q1: How many inputs and what voltage does 1794-IH16 support?
A1: 16 digital inputs at 125 V DC nominal. On-state range 90 to 146 V DC.
Q2: Which terminal bases are compatible?
A2: 1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK terminal bases.
Q3: What is the module weight?
A3: 0.3 kg.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...