Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1771-IFE
Allen-Bradley 1771-IFE PLC-5 Analog Input 16 Single 8 Diff
Manufacturer: Allen-Bradley
Product No.: 1771-IFE
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1771-IFE PLC-5 Analog Input Module
Allen-Bradley 1771-IFE is a PLC-5 analog input module with 16 single-ended or 8 differential channels. Supports voltage and current signals with 12-bit resolution, optoelectrical isolation, and digital filtering. Compatible with any 1771 I/O chassis.
Key Specifications
| Parameter | Value |
|---|---|
| Catalog No. | 1771-IFE |
| Series | PLC-5 |
| Module Type | Analog Input Module |
| Inputs | 16 single-ended or 8 differential |
| Resolution | 12-bit binary / 12 bits plus sign bipolar |
| Accuracy | 0.1% of full scale @ 25°C |
| Backplane Current | 750 mA |
| Max Power Dissipation | 2.5W |
| Weight | 0.5 kg |
Input Signal Ranges
| Signal Type | Range |
|---|---|
| Voltage | 1-5V, 0-5V, -5 to +5V, -10 to +10V, 0-10V DC |
| Current | 4-20mA, 0-20mA, -20 to +20mA |
Update & Scan Rate
| Parameter | Value |
|---|---|
| Channel Update (8 ch) | 18 ms |
| Channel Update (16 ch) | 36 ms |
| Internal Scan (8 diff) | 12.5 ms + 2.12 ms filtering |
| Internal Scan (16 SE) | 25 ms + 4.24 ms filtering |
Features
- Block transfer programming for PLC interface
- Optoelectrical isolation protects against electrical transients
- Input filtering reduces electrical noise
- Natural Binary or BCD scaling to ±9999
- Green RUN and red FAULT front panel indicators
- 1771-WG wiring arm allows module replacement without rewiring
- Keying bands between pins 10-12 (lower) and 24-26 (upper)
FAQs
Q1: How many input channels does the 1771-IFE have?
A1: 16 single-ended or 8 differential inputs.
Q2: What is the resolution?
A2: 12-bit binary or 12 bits plus sign on bipolar ranges.
Q3: What wiring arm is included?
A3: 1771-WG wiring arm.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...