Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1771-IC
Allen-Bradley 1771-IC | Input Module 8 Point 42-56V DC
Manufacturer: Allen-Bradley
Product No.: 1771-IC
Product Type: Digital DC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
1771-IC Allen-Bradley PLC 5 Digital DC Input Module – 8 Channels 42-56V DC
The Allen-Bradley 1771-IC is a PLC 5 digital DC input module with 8 input channels. Operates with a 42-56V DC range and 10-60V DC sink voltage category. Weight is approximately 0.45 kg.
Product Information
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1771-IC |
| Module Type | Digital DC Input Module |
| Number of Inputs | 8 |
| Voltage Category | 10-60V DC Sink (Source Load) |
| DC Operating Voltage | 42-56V DC |
| Coating | Conformal Coat |
| Wiring Arm | 1771-WN |
| Dimensions | 89 x 165 x 51 mm |
| Weight | Approx. 0.45 kg |
Input Specifications
| Max DC Off-State Current | 3.7 mA |
| Typical Signal Delay (On) | 17 ms (±7 ms) |
| Typical Signal Delay (Off) | 20 ms (±7 ms) |
| 3-Wire Off-State Leakage (Max) | 4 mA |
Power Specifications
| Backplane Current | 74 mA |
| Input Filtering | Yes (Suppresses Electrical Noise and Contact Bounce) |
| ESD Protection | Static-Shield Bag |
Features
- 8 digital DC input channels
- 42-56V DC operating voltage range
- 10-60V DC sink (source load) voltage category
- Input filtering suppresses voltage transients and contact bounce
- Conformal coating for environmental protection
- Shipped in static-shield bag for ESD protection
- 1771-WN wiring arm for module replacement without rewiring
- Compatible with 2-wire and 3-wire devices
FAQs
Q1: How many inputs does the 1771-IC provide?
A1: 8 digital DC input channels.
Q2: What is the operating voltage and signal delay?
A2: 42-56V DC operating range with 17 ms (±7 ms) on delay and 20 ms (±7 ms) off delay.
Q3: What wiring arm and backplane current are required?
A3: 1771-WN wiring arm with 74 mA backplane current.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...