Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1762-OX6I
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Module
Manufacturer: Allen-Bradley
Product No.: 1762-OX6I
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 220g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Output Module
Allen-Bradley 1762-OX6I | MicroLogix 1200 series isolated relay output expansion module with 6 individually isolated Form C contact outputs. Compatible with MicroLogix 1100, 1200, and 1400 controllers. Each output provides one Normally Open and one Normally Closed terminal for flexible switching. DIN rail or panel mounting. Weight: approximately 220 g (0.485 pounds).
Key Features
6 individually isolated Form C relay outputs. Operating voltage range 5-125VDC and 5-265VAC. 7 A continuous current per point. 10 ms maximum ON signal delay, 20 ms maximum OFF delay. 110 mA bus current draw at 5VDC and 24VDC. 6 isolated groups (outputs 0-5). Flat ribbon cable with female bus connector. Power supply distance rating 6. Requires 2-inch clearance on all sides for airflow. Compatible with MicroLogix 1100/1200/1400.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-OX6I |
| Product Family | MicroLogix 1200 |
| Product Type | Discrete Output Module |
| No. of Outputs | 6 (Isolated Relay) |
| No. of Groups | 6 (individually isolated) |
| Output Form | Type C Relay (1 N.O. + 1 N.C.) |
| Output Voltage Range | 5-125V DC; 120/240V AC |
| Operating Voltage Range | 5-264V AC; 5-125V DC |
| Voltage Category | AC/DC Type |
| Continuous Current per Point | 7 A |
| Signal Delay (ON) | 10 ms max (6 ms typical) |
| Signal Delay (OFF) | 20 ms max (12 ms typical) |
| Bus Current Draw | 110 mA @ 5V DC; 110 mA @ 24V DC |
| Power Supply Distance Rating | 6 |
| Compatible Controllers | MicroLogix 1100 / 1200 / 1400 |
| Mounting Type | DIN Rail or Panel Mount |
| Connection | Flat ribbon cable with female bus connector |
| Dimensions (H x W x D) | 90 x 40.4 x 87 mm (3.54 x 1.59 x 3.43 in) |
| Weight | Approx. 220 g (0.485 lbs) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Maximum Altitude | 2000 m (6561 ft) |
Installation Notes
Leave 2-inch (50.8 mm) clearance on all sides of the module for proper airflow and to prevent overheating. Mount on DIN rail with end anchors, or use two Panhead screws per module for high-vibration environments. Connect to the controller and adjacent I/O modules using a flat ribbon cable with female bus connector. Up to 4 modules can be used with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Engineering Advantages
Individually isolated Form C relays allow each channel to switch independent circuits, simplifying mixed-voltage installations. High 7 A per point rating handles demanding loads directly without interposing relays. Form C contacts provide both normally open and normally closed options on every channel. Dual AC/DC voltage capability eliminates the need for separate output module types. Compact 220 g design with flexible mounting options simplifies panel layout.
FAQs
Q1: How many outputs does this module provide?
A1: 6 individually isolated Form C relay outputs.
Q2: What is the maximum current per point?
A2: 7 A continuous current per point.
Q3: How many modules can be connected to each controller?
A3: Up to 4 with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
