Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1762-L40BXBR
Allen-Bradley 1762-L40BXBR | 20 In 16 Out MicroLogix PLC
Manufacturer: Allen-Bradley
Product No.: 1762-L40BXBR
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1762-L40BXBR is a MicroLogix 1200 Programmable Logic Controller with 40 total I/O channels. It provides 20 standard 24VDC sink/source inputs and 4 fast 24VDC inputs. The output section includes 8 relay, 7 24VDC FET, and 1 high-speed 24VDC FET. Weighing 1.1 kilograms, this controller supports up to 6 expansion I/O modules for flexible system growth.
Technical Configuration
The controller features 2 trim potentiometers configurable for simulation and control purposes. Two communication ports include 1 programming port and 1 primary communication interface for HMI, SCADA, gateways, and intelligent electronic devices. The relay output supports a maximum load of 1440VA with 8A maximum current per group and 30A overall per point at 150V. Isolation voltage is 75VDC between input group and backplane, dielectrically tested at 1200VAC for 1 second.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Series | MicroLogix 1200 |
| Part Number | 1762-L40BXBR |
| Inputs | 24 (20 standard 24VDC + 4 fast 24VDC) |
| Outputs | 16 (8 relay, 7 FET, 1 high-speed FET) |
| Power Supply | 24VDC external |
| Output Currents | 600 mA at 5VDC, 500 mA at 24VDC |
| Power Consumption | 40 Watts |
| Power Supply Usage | 82 VA |
| Inrush Current | 120VAC: 25A for 8 ms; 240VAC: 40A for 4 ms |
| Relay Contact Rating | 24-125VDC; 120-240VAC |
| Load Current | 10A minimum |
| Mechanical Cycles | 20,000,000 |
| Heat Dissipation | 27.9 Watts |
| Dimensions (H x W x D) | 90 x 160 x 87 mm (104 mm with DIN latch open) |
| Weight | 1.1 kg (2.4 lbs) |
| Operating Temperature | 0 to 55°C (32 to 131°F) |
| Storage Temperature | -40 to +85°C (-40 to +185°F) |
| Humidity | 5% to 95% non-condensing |
| Operating Shock | 30 G |
| Vibration | 5G at 10 to 500 Hz |
| Communication Ports | 1 programming port, 1 8-pin mini-DIN serial port |
| Protocols | DF1, DH-485, ASCII, Modbus |
| Certification | UL, c-UL, CE |
Installation Guide
Mount the controller on a panel or DIN rail using the integrated latch. Connect external 24VDC power to the designated terminals. Wire inputs and outputs using removable terminal blocks. Do not exceed 8A per group common rating. Install up to 6 expansion I/O modules for system growth. Use the 8-pin mini-DIN port for HMI, SCADA, or programming connections. Maintain 5% to 95% non-condensing humidity.
Engineering Advantages
This controller delivers 40 I/O channels in a 160 mm wide housing. Four fast inputs support high-speed counting applications. Two trim potentiometers enable analog simulation without external hardware. The relay output provides 1440VA maximum load capacity. Isolation of 75VDC protects the backplane from field transients. UL, c-UL, and CE certifications ensure global compliance.
Technical FAQs
Q1: How many expansion modules can the 1762-L40BXBR support?
A1: This controller supports up to 6 pieces of 1762 expansion I/O modules for system expansion.
Q2: What is the relay output maximum load?
A2: The relay output supports a maximum load of 1440VA with 8A maximum current per group and 30A overall per point at 150V.
Q3: What isolation voltage does this controller provide?
A3: The 1762-L40BXBR provides 75VDC isolation between input group and backplane, dielectrically tested at 1200VAC for 1 second.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...