Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1762-IF2OF2
Allen-Bradley 1762-IF2OF2 MicroLogix 1200 1400 Expansion Module
Manufacturer: Allen-Bradley
Product No.: 1762-IF2OF2
Product Type: Expansion Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 240g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1762-IF2OF2 MicroLogix Combination Analog I/O Module
The Allen-Bradley 1762-IF2OF2 is a compact combination analog I/O expansion module designed for MicroLogix 1100, 1200, and 1400 programmable logic controller platforms. Providing a space-saving and cost-effective automation solution, this unit features two differential analog inputs and two single-ended analog outputs configurable for 0 to 10 VDC voltage or 4 to 20 mA current signals. Equipped with 12-bit unipolar resolution, successive approximation A/D conversion, and robust channel diagnostics, the 1762-IF2OF2 delivers precise signal processing for process control devices such as modulating valves, drives, and transmitters. Weighing approximately 0.24 kg (0.53 lbs), it connects via an integrated bus ribbon cable for DIN rail or panel mounting.
Technical Specifications
| Manufacturer & Brand | Allen-Bradley / Rockwell Automation |
| Catalog Number / Part No. | 1762-IF2OF2 |
| Product Family Compatibility | MicroLogix 1100 / 1200 / 1400 Controller Systems |
| Module Functionality | 2-Input / 2-Output Combination Analog Expansion Module |
| Input & Output Signal Ranges | Voltage: 0 to 10 VDC (0–10.5V Full Range) | Current: 4 to 20 mA (0–21 mA Full Range) |
| Channel Configuration | 2 Differential Inputs | 2 Single-Ended Outputs |
| Resolution & Conversion Method | 12-Bit Unipolar Resolution | Successive Approximation ADC / Resistor String DAC |
| Bus Current Draw | 40 mA @ 5 VDC | 105 mA @ 24 VDC |
| Operating Temperature Limits | -20°C to +65°C (-4°F to +149°F) |
| Dimensions & Net Weight | 90 x 87 x 40 mm (3.54 x 3.43 x 1.58 in) | Approx. 0.24 kg (0.53 lbs) |
Quick Installation Guide
- Mount the module adjacent to the main MicroLogix controller on a standard DIN rail or using direct panel mounting screws.
- Connect the attached flat ribbon bus cable to the expansion connector on the adjacent controller or existing expansion module.
- Wire input and output field devices using shielded twisted-pair cables and verify proper grounding to minimize electrical noise interference.
Technical FAQs
Q1: What signal types are supported on the inputs and outputs of the 1762-IF2OF2 module?
A1: Both the two inputs and two outputs can be individually configured for 0 to 10 VDC voltage or 4 to 20 mA current signals.
Q2: Which Allen-Bradley controller families are compatible with the 1762-IF2OF2 expansion module?
A2: It is natively compatible with Allen-Bradley MicroLogix 1100, MicroLogix 1200, and MicroLogix 1400 PLC platforms.
Q3: What conversion resolution and update rate does the 1762-IF2OF2 deliver?
A3: It features 12-bit unipolar analog conversion resolution with a fast input update time of 2.5 ms.
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
