Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-OW16IK
Allen-Bradley 1756-OW16IK | Isolated Relay Output 16-Point
Manufacturer: Allen-Bradley
Product No.: 1756-OW16IK
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 414g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1756-OW16IK is a conformally-coated Isolated Relay Output Module for ControlLogix 5580 controllers. It provides 16 normally open, individually isolated outputs rated for 10-265V AC and 5-150V DC operation. The module weighs 0.414 kg and fits a single rack slot for flexible system integration.
Core Functionality
The 1756-OW16IK drives pilot duty loads such as relays, contactors, and solenoids with C300/R150 pilot duty rating. Each of the 16 outputs is individually isolated, preventing cross-channel faults. Maximum output delay time is 10ms for responsive switching. The module communicates with Logix5000 controllers via rack-optimized or direct connections, supporting both local and remote chassis installation over EtherNet, ControlNet, or IP networks.
Technical Specifications
| Parameter | Value |
| Part Number | 1756-OW16IK |
| Series | ControlLogix |
| Module Type | Isolated Relay Output Module |
| Outputs | 16 (individually isolated, N.O.) |
| Operating Voltage | 10-265V AC / 5-150V DC |
| Output Current | 2A / 0.5A / 0.25A (load dependent) |
| Max Output Delay | 10 ms |
| Min Load Current per Point | 10 mA |
| Pilot Duty Rating | C300 / R150 |
| Backplane Current (5V / 24V) | 150 mA / 150 mA |
| Power Dissipation (Max) | 4.5W at 60°C |
| Thermal Dissipation | 15.35 BTU/hr |
| Isolation Voltage | 250V continuous |
| Initial Contact Resistance | 100 mΩ at 6V, 1A |
| Expected Contact Life | 300k resistive / 100k inductive |
| Terminal Blocks | 1756-TBCH / 1756-TBS6H |
| Operating Temperature | 0°C to 60°C |
| Weight | 0.414 kg (0.91 lbs) |
Installation Guide
Insert the 1756-OW16IK into any single ControlLogix chassis slot. Power down the chassis before insertion to avoid arc hazards in hazardous locations. Connect field wiring using 1756-TBCH or 1756-TBS6H removable terminal blocks, or a Bulletin 1492 IFM. Observe load-dependent current limits per channel. Verify output status via onboard indicators after configuration.
Engineering Advantages
This module delivers 16 individually isolated outputs, preventing a single field fault from affecting other channels. Conformal coating protects against moisture, dust, and corrosive contaminants. The 250V continuous isolation rating ensures safe separation from the backplane. Expected contact life of 300k resistive operations supports long service intervals. Real-time diagnostics via onboard indicators simplify troubleshooting.
Technical FAQs
Q1: What output configuration and voltage range does this module provide?
A1: 16 normally open individually isolated outputs. 10-265V AC and 5-150V DC operating range.
Q2: What is the load-dependent current rating?
A2: 2A, 0.5A, or 0.25A depending on voltage. Minimum load current 10mA per point. C300/R150 pilot duty.
Q3: Which terminal blocks are compatible?
A3: 1756-TBCH and 1756-TBS6H removable terminal blocks, or a Bulletin 1492 IFM.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...