Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-L65
Allen-Bradley 1756-L65 ControlLogix 5565 Processor 32MB Memory
Manufacturer: Allen-Bradley
Product No.: 1756-L65
Product Type: Processor Controller
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1756-L65 is a high-capacity, single-slot PLC processor belonging to the powerful Logix5565 controller line. Engineered to anchor heavy industrial applications, it features an expansive 32 Mbytes of volatile user program memory and a dedicated 478 Kbytes of high-speed I/O memory. Designed for flexible system scaling, the 1756-L65 supports a massive total capacity of up to 128,000 I/O points (including up to 4,000 analog points) and executes up to 32 independent multi-tasking routines simultaneously. Weighing 0.35 kg (0.77 lbs), this advanced controller slots directly into any standard Allen-Bradley ControlLogix chassis to deliver deterministic processing across massive automated plant infrastructures.
Core Technical Advantages
- Massive 32MB User Memory Matrix: Provides ample room for large user logic code, extensive data logging structures, and advanced mathematical scripting blocks, eliminating the need to segment complex programs.
- True Multitasking Logic Engine: Handles 32 tasks simultaneously (1 continuous task and up to 31 periodic or event-driven tasks) to easily prioritize time-critical machine motions over background calculations.
- Industrial Toughness & Isolation: Tested for 720 VDC structural isolation, 30G operational shock waves, and continuous 2.0G plant floor vibrations across a 0 to 60 degrees Celsius thermal window.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix Series) |
| Model Part Number | 1756-L65 (Logix5565 Series) |
| Gross Weight | 0.35 kg (0.77 lbs) |
| User Program Memory | 32 Megabytes volatile RAM storage matrix |
| Dedicated I/O Memory | 478 Kilobytes fast buffer configuration |
| Non-Volatile Memory Slot | Supports up to 128MB CompactFlash storage card (1784-CF128) |
| Total System I/O Capacity | 128,000 total discrete lines / 4,000 analog words max |
| Integrated Interfaces | 1 Built-in RS-232 serial link port (DF1 / DH-489 channels) |
| Total Supported Connections | Up to 250 logical communications paths |
| Backplane Slot Allocation | Single-slot standard width format |
| Backplane Current Demands | 1200 mA at 5.1 VDC bus lines / 14 mA at 24 VDC potential |
| Power & Thermal Dissipation | 3.5 Watts total consumption / 11.9 BTU/hour thermal output |
| Battery Model Reference | 1756-BA2 replaceable lithium battery pack |
Installation & Engineering Guide
- Chassis Mounting & Layout: The 0.35 kg CPU module can be hot-swapped or cold-inserted into any slot position within a standard ControlLogix chassis (such as the 1756-A4, A7, A10, A13, or A17 frameworks). Line up the circuit edges with the chassis guide tracks, pushing firmly back until both the upper and lower plastic retaining tabs snap securely onto the metal structure to support the unit against plant floor vibrations.
- Non-Volatile Flash Configuration: To protect your 32MB application code against power failures, insert a compatible CompactFlash card into the front memory slot. Through Studio 5000, engineers can configure the processor to boot up automatically from the card during power-on, ensuring zero runtime data loss.
- Network Architecture Integration: While the 1756-L65 includes a native RS-232 serial port for diagnostic laptops or legacy networks, large-scale plant distributions should run alongside dedicated communication bridge cards (like the 1756-EN2T for EtherNet/IP, 1756-CN2 for ControlNet, or 1756-DNB for DeviceNet links).
Technical FAQs
Q1: What happens if the onboard battery fails on the 1756-L65 processor?
A1: The 1756-L65 utilizes volatile RAM to maintain runtime logic. If the 1756-BA2 lithium battery dies while the chassis loses power, the volatile 32MB memory will drop its program. To prevent this downtime, we highly recommend storing a permanent copy of your application logic on an optional CompactFlash card.
Q2: Can the 1756-L65 communicate directly over EtherNet/IP out of the box?
A2: The processor only features a built-in RS-232 serial port. To link the 1756-L65 to an EtherNet/IP network, you must add an adjacent Ethernet communication module, such as the 1756-EN2T or 1756-ENBT, into the same ControlLogix backplane chassis.
Q3: Does the 0.35 kg mechanical weight place limits on where I can install the card inside the chassis?
A3: Not at all. The compact 0.35 kg balance is distributed across a single-slot standard width footprint. Thanks to its native direct backplane connection system, it operates with full efficiency in any open slot location of your rack, though slot 0 is the common engineering standard for the main CPU.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...