Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-IF6I
Allen-Bradley 1756-IF6I ControlLogix Analog Input Module 6-Point
Manufacturer: Allen-Bradley
Product No.: 1756-IF6I
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 680g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1756-IF6I ControlLogix Analog Input Module
Allen-Bradley 1756-IF6I is an isolated analog input module for the ControlLogix system. Features 6 individually isolated channels supporting ±10.5V, 0-10.5V, 0-5.25V, and 0-21 mA input signals. 16-bit resolution with Sigma-Delta conversion. Weight: 0.68 kg (1.5 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Model | 1756-IF6I |
| Product Type | Isolated Analog Input Module |
| Series | ControlLogix |
| Number of Inputs | 6 points, isolated |
| Input Signal Range | ±10.5V, 0-10.5V, 0-5.25V, 0-21mA |
| Input Resolution | 16 bits |
| Conversion Method | Sigma-Delta |
| Data Format | Integer mode, IEEE 32-bit floating point |
| Backplane Current (5V) | 250 mA |
| Backplane Current (24V) | 100 mA |
| Power Dissipation (Voltage) | 3.7 W |
| Power Dissipation (Current) | 4.3 W |
| Removable Terminal Blocks | 1756-TBNH, 1756-TBSH |
| Weight | 0.68 kg (1.5 lbs) |
Input Signal Resolution
| Range | Resolution per Bit |
| ±10.5V | 343 µV/bit |
| 0 to 10.5V | 171 µV/bit |
| 0 to 5.25V | 86 µV/bit |
| 0 to 21mA | 0.34 µA/bit |
Key Features
- 6 individually isolated analog input channels
- Sigma-Delta conversion method for high accuracy
- Supports scaling to engineering units for HMI and SCADA integration
- Wire off detection for each channel
- Rate alarm monitoring for floating-point mode applications
- Process alarms for high/low limit exceedance
- Digital filter for noise transient smoothing
- Real-time sampling with adjustable RTS periods
Installation Guidelines
Terminal Blocks: Requires either 1756-TBNH or 1756-TBSH 20-pin Removable Terminal Block for wiring input signals.
RPI Configuration: Set requested packet interval (RPI) and real-time sampling (RTS) periods during module configuration.
Power Requirements: Draws 250 mA at 5V and 100 mA at 24V from backplane. Max power dissipation 4.3 W.
Notch Filter Selection: Choose the notch filter that closest matches anticipated noise frequency to optimize effective resolution.
FAQs
Q1. What terminal blocks are compatible with the 1756-IF6I?
A1. The module requires either the 1756-TBNH or 1756-TBSH 20-pin Removable Terminal Block for wiring input signals.
Q2. What signal ranges does the module support?
A2. The module supports ±10.5V, 0-10.5V, 0-5.25V, and 0-21 mA ranges with 16-bit resolution.
Q3. What data formats are available?
A3. The module supports two data formats: integer mode (left justified, 2's complement) and IEEE 32-bit floating point.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...
-
Can Bently Nevada + GE Fanuc PLC Prevent Mill Shutdowns?
This article examines Bently Nevada sensors integrated with GE Fanuc PLC for predictive maintenance in metallurgy. 20...
-
What Is the Data-Driven Strategy for Guaranteeing Genuine Control Spares?
Fragmented spare parts procurement causes 68% of unplanned plant shutdowns and inflates costs by 22% annually. This e...
-
Can GE Fanuc-Emerson Integration Cut OPEX 18%?
A regional refinery cut downtime 28% and energy use 18% via GE Fanuc PLC-Emerson DCS integration. Retained legacy har...
-
Why Do 78% of Digital Retrofits Fail Without Edge Data?
This technical article examines how Emerson's industrial edge gateway resolves multi-vendor OT interoperability chall...