Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1734-IK
Allen-Bradley 1734-IK | POINT I/O Incremental Encoder Module
Manufacturer: Allen-Bradley
Product No.: 1734-IK
Product Type: Encoder Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1734-IK is a POINT I/O incremental encoder module with 1 counter input. It accepts 15-24V DC input voltage with 6.1 mA current at 15V DC and 10.2 mA at 24V DC. Weighing 0.08 pounds, this open-style module processes frequencies up to 1 MHz and returns counts as a 24-bit binary number in a 32-bit long word. The key switch position is 2 with wiring category 1 on all signal ports.
Technical Configuration
This module provides one input group with A/A, B/B, and Z/Z returns for differential or single-ended encoder feedback. It receives signals from pulse generators, differential or single-ended encoders, and mechanical limit switches. Five status indicators show module state, network status, and A, B, and Z input states. The module mounts on a DIN rail and is compatible with 1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S wiring base assemblies using 22 to 14 AWG copper wire.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IK |
| Series | POINT I/O |
| Module Type | Incremental Encoder Module |
| Counter | 1 |
| Input Voltage | 15-24V DC (nominal 24V DC) |
| Input Current | 6.1 mA @ 15V DC; 10.2 mA @ 24V DC |
| Max Frequency | 1 MHz |
| Count Format | 24-bit binary (0-16,777,215) in 32-bit long word |
| Off-State Current/Voltage | ≤ 0.250 mA / ≤ 1.8V DC |
| On-State Current/Voltage | ≥ 5 mA / ≤ 12.5V DC |
| Max POINT Bus Current | 160 mA |
| Max Power Dissipation | 1.5 W at rated load |
| Max Thermal Dissipation | 5.1 BTU/hour at rated load |
| Key Switch Position | 2 |
| Wiring Category | 1 |
| Status Indicators | 5 LEDs (module, network, A, B, Z) |
| Enclosure Type | None (Open-Style) |
| Dimensions | 2.21 x 0.47 x 2.97 in |
| Weight | 0.08 lbs |
| Operating Temperature | -20 to 55°C |
| Relative Humidity | 5-95% non-condensing |
| Operating Vibration | 5 g at 10-500 Hz |
Installation Guide
Mount the 1734-IK on a DIN rail using a compatible 1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S wiring base assembly. Wire connections with 22 to 14 AWG stranded or solid copper wire. No external DC power supply is required for operation. Verify input signals from differential or single-ended encoders, pulse generators, or mechanical limit switches connect to the A/A, B/B, and Z/Z returns. Confirm key switch position 2 and wiring category 1 requirements during commissioning.
Engineering Advantages
This module processes encoder frequencies up to 1 MHz, supporting high-speed motion and counting applications. The 24-bit binary count resolution enables precise position tracking across 16,777,215 counts. Five LED indicators provide immediate visibility into module, network, and input states for rapid troubleshooting. Compatibility with both differential and single-ended encoders plus mechanical limit switches offers flexible field device integration. The open-style design eliminates external DC power supply requirements, simplifying cabinet wiring.
Technical FAQs
Q1: What encoder types does the 1734-IK support?
A1: This module accepts feedback from differential or single-ended encoders and pulse generators, plus mechanical limit switches, with A/A, B/B, and Z/Z input returns.
Q2: What is the maximum input frequency?
A2: The 1734-IK processes frequencies up to 1 MHz and returns counts as a 24-bit binary number in a 32-bit long word.
Q3: What wiring base assemblies are compatible?
A3: Compatible wiring bases include 1734-TB, 1734-TBS, 1734-TB3, and 1734-TB3S, using 22 to 14 AWG copper wire.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...