Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1734-IB2
Allen-Bradley 1734-IB2 24VDC Digital Input Terminal Module
Manufacturer: Allen-Bradley
Product No.: 1734-IB2
Product Type: Digital Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 31g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 1734-IB2 is a compact, high-performance 24 VDC Digital Sinking Input Module engineered by Allen-Bradley (Rockwell Automation) for the versatile POINT I/O System. Built to facilitate seamless field device connectivity across ControlNet, DeviceNet, and EtherNet/IP networks, this module features Two (2) discrete sinking input channels designed to monitor 24V DC logic signals in industrial automation systems. Operating across a field supply range of 10 to 28.8 VDC (24 VDC nominal) with a maximum input current of 5 mA per channel, it mounts onto a designated removable terminal block (RTB) base with a mechanical keyswitch set to Position 1. Featuring an ultra-lightweight hardware net weight of 30.9 g (0.0309 kg / 1.09 oz), an open-style enclosure rating, and an extended operating temperature range from -20°C to +55°C, this module draws just 75 mA of POINTBus backplane current at 5V DC.
As depicted in the product image, the module features a slice form-factor with integrated diagnostic LEDs, side mounting latching mechanisms, and precise terminal base alignment slots for quick vertical or horizontal installation.
Core Technical Advantages
- Flexible Multi-Network Connectivity: Integrates effortlessly into distributed architectures managed via EtherNet/IP, ControlNet, DeviceNet, and other open industrial network protocols.
- Low-Power Sinking Inputs: Features 2 sinking input points with low heat generation, consuming only 0.7 W maximum power dissipation at 28.8 VDC for improved panel thermal management.
- Mechanical Keyed Safety Base: Designed for mechanical Keyswitch Position 1 on the mounting base to prevent module misplacement during installation and field replacement.
- Versatile Enclosure Mounting: Open-style slice housing supports both horizontal and vertical mounting orientations without thermal derating up to 55°C.
Technical Specifications
| Parameter Attribute | Factory Specification Data |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Catalog / Part Number | 1734-IB2 |
| Product Family Series | POINT I/O System |
| Module Functional Type | Digital DC Sinking Input Module |
| Number of Inputs | 2 Channels (Sinking Type) |
| Nominal Input Voltage | 24 VDC |
| Input Voltage Range | 10.0..28.8 VDC |
| Maximum Input Current | 5 mA per channel |
| POINTBus Backplane Current | 75 mA @ 5V DC |
| Power / Thermal Dissipation | 0.7 W Max @ 28.8 VDC | 2.4 BTU/hr Max @ 28.8 VDC |
| Physical Net Weight | 30.9 g (0.0309 kg / 1.09 oz) |
| Dimensions (H x W x D) | 56.0 x 12.0 x 75.5 mm (2.21 x 0.47 x 2.97 in) |
| Keyswitch Position & Torque | Position 1 | Terminal Screw Torque: 0.8 N-m (7 lb-in) |
| Operating Temperature Range | -20°C to +55°C (-4°F to +131°F) |
| Condition / Warranty | New & Original in Sealed Packaging | 12-Month Factory Warranty |
Installation & Field Maintenance Guidelines
Mount on RTB base with keyswitch at Position 1. Tighten terminal screws to 0.8 N-m. Verify 10-28.8VDC supply before power-up.
Technical FAQs
Q: Key position?
A: Set base keyswitch to Position 1.
Q: Power specs?
A: 24VDC nominal (10-28.8VDC range), 5mA max current.
Q: Bus current?
A: Draws 75 mA max from 5VDC POINTBus.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...
-
How Does 3500/22M Improve Mixed-Vendor Safety Integration?
This article examines the measurable performance gap between Bently Nevada's legacy 3500/22 and the upgraded 3500/22M...
-
Fixed Gas Detector or Transmitter: Which Fits Your Plant?
This article examines the practical differences between fixed gas detectors and gas detection transmitters in industr...
