Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:V18345-1010221001
ABB V18345-1010221001 Valve Positioner | Original Stock
Manufacturer: ABB
Product No.: V18345-1010221001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
ABB V18345-1010221001 Valve Positioner
The V18345-1010221001 (also cataloged as the V18345 Valve Positioner) is a TZIDC-120 intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire input and provides single-acting, fail-freeze output for linear actuators to DIN/IEC 534 / NAMUR or rotary actuators to VDI/VDE 3845. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-1010221001 |
| Brand | ABB |
| Product Type | Valve Positioner (TZIDC-120) |
| Enclosure | Aluminium, varnished, IP 65 (NEMA 4X) |
| Weight | 1.7 kg |
| Input Signal | 4-20 mA, two-wire |
| Input Limit | Max. 25 mA / 30 V |
| Impedance at 20 mA | 435 ohms |
| Output Range | 0 to 6 bar (0 to 90 psi) |
| Air Capacity at 6 bar | 13 kg/h = 10 Nm3/h = 6.0 scfm |
| Output Function | Single acting, fail freeze |
| Pneumatic Connections | Air pipe: Thread 1/4-18 NPT |
| Electrical Connections | Cable: Thread 1/2-14 NPT |
| Position Feedback | Plug-in analog module, 4-20 mA |
| Explosion Protection | Without |
Electropneumatic Control Characteristics
The V18345 positioner uses two-wire technology with a nominal 4-20 mA range and supports split range configuration between 20 % and 100 % of nominal range. Minimum operating current is 3.4 mA without analog position feedback and 3.5 mA with the feedback module installed; start-up is from 3.8 mA. Load voltage at 20 mA is 8.7 V DC with a 435 ohm input impedance. A digital input accepts 24 V DC (12-30 V DC), with 0-10 V DC interpreted as logical 0 and 12-30 V DC as logical 1, drawing a maximum of 4 mA. The digital output follows the DIN 19234/NAMUR control circuit at 5-11 V DC, with less than 1.0 mA as logical 0 and greater than 2.0 mA as logical 1. Pneumatic output spans 0 to 6 bar (0 to 90 psi); air capacity at a 6 bar supply is 13 kg/h (10 Nm3/h, 6.0 scfm). Shut-off values are adjustable to 0-45 % at end position 0 % and 55-100 % at end position 100 %. The unit weighs 1.7 kg.
Field Installation Guidelines
Mount the positioner to a linear actuator per DIN/IEC 534 / NAMUR or to a rotary actuator per VDI/VDE 3845 using the mechanical kit. Verify the varnished aluminium case remains sealed to maintain IP 65 (NEMA 4X) integrity. Confirm the 1.7 kg unit is supported by the actuator mounting bracket during installation. Connect the 4-20 mA two-wire input through the 1/2-14 NPT cable entry and the air supply through the 1/4-18 NPT air pipe port. Confirm supply air is dry and oil-free at or below 6 bar before pressurizing. Route signal wiring separately from AC power conductors. Set the split range and fail-freeze action in configuration before placing the loop in service. Verify shut-off values at both end positions after commissioning.
Frequently Asked Questions
Q: What is the input signal and impedance of the V18345-1010221001?
A: 4-20 mA two-wire input with 435 ohms impedance at 20 mA.
Q: What is the fail-safe action of this configuration?
A: Single acting, fail freeze.
Q: What are the pneumatic and electrical connection thread sizes?
A: Air pipe: 1/4-18 NPT; cable: 1/2-14 NPT.
Additional Specifications
- Silver
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...