Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TB825
ABB TB825 3BSE036634R1 S800L ModuleBus Slave Module
Manufacturer: ABB
Product No.: TB825
Product Type: Communication Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 210g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
ABB TB825 3BSE036634R1 S800L Module
The ABB TB825 3BSE036634R1 belongs to the S800L series. It is a ModuleBus slave communication module. This unit supports plastic and HCS optical fiber conversion. It mounts directly on DIN rail.
Technical Specifications
- Brand: ABB
- Model: TB825
- Series: S800L
- Article Number: 3BSE036634R1
Key Features
- Communication Protocol: ModuleBus
- Master or Slave: Slave
- DIN Rail Mounted: Yes
- Multi-Mode Functionality: Supports plastic and HCS optical fiber conversion
Environmental Specifications
- Operating Temperature: 0 to +55°C (+32 to +131°F)
- Storage Temperature: -40 to +70°C (-40 to +158°F)
- Relative Humidity: 5 to 95%, non-condensing
- Corrosion Protection: ISA-S71.04 G3
- Power Consumption: 96 mA at 24V DC
Dimensions and Weight
- Width: 85.6 mm (3.37 in)
- Height: 136 mm (5.35 in) including latch
- Depth: 58.5 mm (2.30 in)
- Weight: 0.21 kg (0.46 lbs)
Compliance and Certifications
- Protection Class: IP20 (EN 60529, IEC 529)
- CE Marking: Yes
- Marine Certifications: ABS, BV, DNV-GL, LR
- RoHS Compliance: Yes (2011/65/EU, EN 50581:2012)
- WEEE Compliance: Yes (2012/19/EU)
Electrical Safety and Hazardous Location
- Electrical Safety: EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201
- Hazardous Location: C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2
Mounting Limits
- Max Ambient Temperature for Vertical Mounting: 40°C (104°F)
Package and Shipping
- Includes: ABB TB825 3BSE036634R1 module. Documentation included.
- Shipping: Via FedEx, UPS, or DHL worldwide.
FAQ
-
What communication protocol does this module use?
The TB825 uses ModuleBus protocol and operates as a slave device. -
What certifications does it hold?
It has ATEX Zone 2, C1 Div 2, marine certifications (ABS, BV, DNV-GL, LR), and CE marking. -
What is the power consumption?
It consumes 96 mA at 24V DC typical.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...