Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CI857
ABB CI857 3BSE018144R1 | AC 800M INSUM Communication Interface
Manufacturer: ABB
Product No.: CI857
Product Type: Communication Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 550g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The ABB CI857 is a specialized communication interface module tailored for the AC 800M controller. As an INSUM protocol master, it acts as the vital bridge between the control system and intelligent motor control devices. By facilitating the exchange of critical diagnostic and operational data, the CI857 allows for advanced motor management strategies within the ABB Ability™ System 800xA, ensuring optimal performance and protection of high-value industrial motors.
Technical Configuration
This interface module is engineered for high-density motor control integration:
- Protocol Support: Native INSUM protocol implementation for seamless communication with ABB motor control centers.
- Network Capacity: Capable of managing up to 128 downstream INSUM devices per single CI857 module.
- Performance: Fixed transmission speed of 10 Mbps ensures rapid update rates for motor protection and status data.
Technical Specifications
| Feature | Details |
|---|---|
| Article Number | 3BSE018144R1 |
| Operating Mode | INSUM Master |
| Approximate Weight | 0.55 kg (Total shipping weight) |
| Protection Rating | IP20 (per IEC 529) |
| Storage Temperature | -40°C to +70°C |
| Compliance | CE-marked, RoHS, WEEE |
Installation & Maintenance
Physical Deployment: The CI857 mounts directly onto the AC 800M CPU backplane or a dedicated communication expansion base. While the unit is lightweight at 0.55 kg, it must be installed in an environment that maintains the IP20 integrity and avoids condensation, especially during storage where temperatures can range down to -40°C.
System Limits: This module does not support line or module redundancy. For critical motor control loops, system designers should consider distributing INSUM devices across multiple CI857 modules to minimize the impact of a single point of failure.
Engineering Advantages
- Optimized Diagnostics: Provides access to deep-level motor parameters that standard I/O modules cannot capture.
- Standardized Integration: Fully CE and RoHS certified, ensuring adherence to global industrial safety and environmental standards.
- Scalable Architecture: The ability to connect 128 devices per master allows for highly efficient use of rack space in large motor control centers.
Technical FAQs
Q1: Does the CI857 support redundancy?
A1: No, the CI857 3BSE018144R1 is designed for non-redundant configurations and does not offer line or module redundancy options.
Q2: What is the maximum distance for the INSUM network?
A2: The distance depends on the physical layer and cabling used (e.g., LonWorks). Refer to the ABB INSUM System documentation for specific cabling guidelines.
Q3: Can the CI857 be used with AC 800F controllers?
A3: No, this module is specifically designed for the AC 800M series of controllers within the 800xA ecosystem.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
