Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:9905-760
9905-760 Woodward Digital Synchronizer Module
Manufacturer: Woodward
Product No.: 9905-760
Product Type: Digital Synchronizer Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 3200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Woodward 9905-760 is a Digital Synchronizer and Load Control Module for multi‑generator power systems. It measures frequency and phase angle, provides precise synchronisation signals, and regulates load sharing to maintain stable voltage and frequency. Ideal for parallel generator operation in power generation and marine applications.
Core Advantages
Precise Digital Synchronisation
Microprocessor‑based measurement of frequency and phase angle. Synchronises multiple generators before grid connection. Automatic or manual operation modes.
Intelligent Load Control
Monitors load demand and adjusts generator output. Prevents overloading and overheating. Enables efficient load sharing across parallel units.
Communication Ready
Supports LinkNet termination resistor module with screw clamp terminals. Interfaces with other control systems for integrated power management.
Specifications
| Parameter | Value |
|---|---|
| Part Number | 9905-760 |
| Type | Digital Synchronizer + Load Control |
| Synchronisation | Frequency & phase angle measurement |
| Operation Modes | Automatic / Manual |
| Load Control | Demand‑based output regulation |
| Parallel Operation | Multi‑generator support |
| Communication | LinkNet (termination resistor module) |
| Terminals | Screw clamp type |
| Cabinet Enclosure | Six‑sided metal (solid doors recommended) |
| RF Attenuation (door window) | >20 dB (10 kHz–1 GHz) |
| Max Cable Entry Aperture | 152 mm (6 inches) |
| Bonding | Cabinet frame & mounting areas grounded |
Installation Tips
Cabinet Grounding
Use a six‑sided metal enclosure. Solid metal doors are preferred. If a window is required, ensure >20 dB RF attenuation from 10 kHz to 1 GHz.
Cable Entry
Limit cable entry holes to 152 mm (6 inches) maximum aperture. This is critical when RF transmitters (handheld radios) are near cable access points.
Bonding
Bond the cabinet frame and all mounting areas together to ensure proper grounding and EMI protection.
LinkNet Wiring
Use the termination resistor module with screw clamp terminals for reliable communication network termination.
Why Choose 9905-760?
Delivers precise generator synchronisation and load sharing in a single module. Microprocessor‑based control ensures accurate frequency matching. Automatic or manual modes provide operational flexibility. Robust cabinet grounding guidelines ensure reliable performance in EMI‑prone environments. Trusted by power plants and marine vessels worldwide.
FAQs
Q1: What is the difference between automatic and manual modes?
A1: Automatic mode handles synchronisation and load sharing without operator intervention. Manual mode allows operator‑controlled adjustment via external signals.
Q2: Why is the 152 mm cable entry restriction important?
A2: Limits RF interference from handheld radios or transmitters near cable entry points. Prevents EMI coupling into control wiring.
Q3: Can this module synchronise more than two generators?
A3: Yes. The 9905-760 supports parallel operation of multiple generators in a power system.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
-
How to Quantify and Fix Allen‑Bradley HMI Flickering in Cement Plants?
This technical article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering in cement plants...
-
How to Fix HMI Flickering Caused by Power Noise and Vibration?
This article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering faults in cement productio...
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...