Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:8440-1935
8440-1935 Woodward easYgen-3500 Sheet Metal Chassis CPU
Manufacturer: Woodward
Product No.: 8440-1935
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1850g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 8440-1935 (alternatively designated as the easYgen-3500-1-P1) is an advanced genset controller from Woodward's easYgen-3000 series. Housed in a durable sheet metal chassis designed for cabinet installation, this unit features integrated generator group breaker control. Weighing approximately 4.08 lbs (1,850 g) with front panel dimensions of 282W x 216H x 96D mm, it delivers high-precision power management with 16-bit resolution and an Accuracy Class of 0.5.
Core Technical Advantages
- High-Precision Measurement: Engineered to Accuracy Class 0.5 with 16-bit resolution and a wide setting range from 1 to 32,000 A.
- Integrated Breaker Control: Equipped with built-in generator group breaker control for seamless synchronization and switching.
- Isolated Discrete Inputs: Features robust isolated discrete input channels to protect internal circuitry from field electrical noise.
- Rugged Sheet Metal Build: Sturdy 1,850 g chassis built to withstand harsh industrial generator control environments.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Series | Woodward Inc. / easYgen-3000 Series |
| Part Number / Model | 8440-1935 (easYgen-3500-1-P1) |
| Accuracy Class & Resolution | Accuracy Class 0.5; 16-Bit Resolution |
| Current Setting Range | 1 to 32,000 A |
| Discrete Inputs | Isolated Discrete Inputs |
| Chassis & Dimensions | Sheet Metal Chassis; 282W x 216H x 96D mm |
| Net Weight | Approx. 1,850 g (4.08 lbs) |
| Power Factor Circuits | Supports Capacitive, Resistive (Unity 1.00), and Inductive Circuits |
Industrial Solutions
- Standby & Prime Power Generators: Manages automatic start/stop, synchronization, and breaker control for diesel and gas generator sets.
- Multi-Gen Paralleling Systems: Coordinates load sharing and power factor regulation across complex multi-generator installations.
- Industrial Power Management: Provides reliable monitoring and protection in industrial switchgear and utility backup panels.
Wiring & Installation
Cabinet Mounting & Chassis Grounding
Install the controller inside a protective industrial cabinet using the 282W x 216H x 96D mm cutout profile. Do not connect wires directly to the protective earth terminal on the controller body; route any necessary ground connections exclusively through the designated bottom connector.
Current Transformer Safety Precaution
Always ensure that current transformers (CTs) are properly short-circuited before disconnecting wiring from the controller. Failing to short-circuit CTs during disconnection can result in hazardous high voltages, severe personal injury, or death.
Power Factor Configuration
Configure power factor parameters based on your system load type—capacitive, purely resistive (targeting unity 1.00 where voltage and current waveforms are in step), or inductive.
Engineering Advantages
- Advanced Power Factor Management: Accurately calculates real-to-apparent power ratios across resistive, inductive, and capacitive circuit profiles.
- Robust Isolation: Isolated discrete inputs safeguard internal processing components from heavy electrical transients.
- Flexible Switchgear Integration: Built-in breaker control logic streamlines synchronization architecture in generator control panels.
Technical FAQs
Q1: What is the model designation and accuracy class of the 8440-1935?
A1: It is also known as the easYgen-3500-1-P1 and features an Accuracy Class of 0.5 with 16-bit resolution.
Q2: What safety precaution is critical when disconnecting current transformers?
A2: You must short-circuit the current transformer before disconnection to prevent severe injury or death from high voltage.
Q3: What are the physical dimensions and weight of this controller?
A3: Dimensions are 282W x 216H x 96D mm, with a net weight of approximately 1,850 g (4.08 lbs).
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...
