Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:6ES7431-7KF00-0AB0
6ES7431-7KF00-0AB0 Siemens SM 431 Analog Input Thermocouple
Manufacturer: Siemens
Product No.: 6ES7431-7KF00-0AB0
Product Type: Analog Input Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 650g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Siemens 6ES7431-7KF00-0AB0 SIMATIC S7-400 Analog Input Module
Product Overview
Siemens 6ES7431-7KF00-0AB0 is a SIMATIC S7-400 analog input module SM 431 with 8 analog inputs. Features 16 bit resolution with 20 ms conversion time. Supports voltage, current, and thermocouple input ranges. Isolated with single rooting, diagnostics, and alarm functions. Parameterizable temperature compensation with internal or external cold junction.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Siemens |
| Model | 6ES7431-7KF00-0AB0 |
| Series | SIMATIC S7-400 |
| Type | Analog Input SM 431 |
| Analog Inputs | 8 |
| Resolution | 16 bit |
| Conversion Time | 20 ms |
| Backplane Current | 1200 mA max at 5V DC |
| Power Loss | 4.6 W typical |
| Voltage Ranges | ±20mV to ±10V, 1 to 5V |
| Current Ranges | ±3.2mA to ±20mA, 0 to 20mA, 4 to 20mA |
| Thermocouple Types | B, E, J, K, L, N, R, S, T, U |
| Temperature Compensation | Internal, external with Pt100 or socket |
| Integration Time | 2.5 / 16.7 / 20 / 100 ms |
| Interference Suppression | 400 / 60 / 50 / 10 Hz |
| Shielded Cable Length | 200m max |
| Diagnostics | Parameterizable |
| Alarms | Diagnostic, limit value, hardware interrupt |
| Isolation | 1500V DC tested |
| Dimensions W x H x D | 25 x 290 x 210 mm |
| Weight | 650 g |
Installation
Install module in SIMATIC S7-400 rack. Connect analog signals to front connector. Use shielded cable maximum 200m. Connect cold junction compensation for thermocouples. Verify potential separation between channels and backplane bus. Configure diagnostics, alarms, and limit values per application.
Features
8 analog inputs with 16 bit resolution. Supports voltage, current, and thermocouple inputs. Internal temperature compensation or external with Pt100/socket. Parameterizable characteristic linearization for thermocouples. Integration time parameterizable with 400/60/50/10 Hz interference suppression. Channel to channel isolation. Diagnostic alarm and limit value alarm functions. Hardware interrupt capability.
FAQ
Q1: What input types are supported?
A1: Voltage (±20mV to ±10V, 1 to 5V), current (±3.2mA to ±20mA, 0 to 20mA, 4 to 20mA), and thermocouple (B, E, J, K, L, N, R, S, T, U). No RTD or resistance support.
Q2: How does temperature compensation work?
A2: Internal temperature compensation standard. External compensation available with Pt100 or compensation socket 6ES7431-7KF00-6AA0. Dynamic reference temperature value supported.
Q3: What diagnostics are available?
A3: Parameterizable diagnostics function with diagnostic alarm, limit value alarm, and hardware interrupt. Diagnostic information readable via PLC.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...