Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:6ES7431-1KF20-0AB0
6ES7431-1KF20-0AB0 | SM 431 8 AI 14 Bit 0.416ms Siemens
Manufacturer: Siemens
Product No.: 6ES7431-1KF20-0AB0
Product Type: Analog Input Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Siemens 6ES7431-1KF20-0AB0 SIMATIC S7-400 Analog Input Module
Product Overview
Siemens 6ES7431-1KF20-0AB0 is a SIMATIC S7-400 analog input module SM 431 with 8 isolated analog inputs. Features 14 bit resolution with ultra-fast 0.416 ms cycle time. Supports voltage, current, and resistor input ranges. Isolated between channels and backplane bus. Designed for high-speed analog signal acquisition applications.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Siemens |
| Model | 6ES7431-1KF20-0AB0 |
| Series | SIMATIC S7-400 |
| Type | Analog Input SM 431 |
| Analog Inputs | 8 isolated (4 for resistance) |
| Resolution | 14 bit |
| Cycle Time | 0.416 ms |
| Load Voltage | 24V DC |
| Input Current from L+ | 200 mA max |
| Backplane Current | 1000 mA max at 5V DC |
| Power Loss | 4.9 W typical |
| Voltage Ranges | ±1V, ±10V, 1 to 5V |
| Current Ranges | ±20mA, 4 to 20mA |
| Resistor Range | 0 to 600 Ohm |
| Basic Conversion Time | 52 µs |
| Input Filter Time Constant | 15 µs |
| Module Execution Time | 0.42 s (all channels) |
| Shielded Cable Length | 200m max |
| Isolation | 2120V DC bus to analog section |
| Dimensions W x H x D | 25 x 290 x 210 mm |
| Weight | 500 g |
Installation
Install module in SIMATIC S7-400 rack. Connect 24V DC load voltage for 2 wire transmitters. Wire analog signals to front connector. Use shielded cable maximum 200m. Verify potential separation between channels and backplane bus. Configure integration time and filter per application requirements.
Features
8 isolated analog inputs with 14 bit resolution. Ultra-fast 0.416 ms cycle time for high speed applications. Supports voltage (±1V, ±10V, 1 to 5V), current (±20mA, 4 to 20mA), and resistor (0 to 600 Ohm) inputs. Integration time parameterizable with 400/60/50 Hz interference suppression. 15 µs input filter time constant. Potential separation between channels and backplane bus. Compact 25mm width design.
FAQ
Q1: How many analog inputs does this module have?
A1: 8 analog inputs for voltage/current measurement, 4 for resistance measurement. Resolution 14 bit.
Q2: What is the cycle time?
A2: 0.416 ms cycle time. Basic conversion time 52 µs. Module execution time 0.42 s for all channels.
Q3: What is the difference between 1KF10 and 1KF20?
A3: 1KF20 offers faster cycle time (0.416 ms vs 20.1 ms) and supports ±20mA and ±1V ranges but does not support thermocouple or RTD inputs like 1KF10.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...