Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:51308353-175
51308353-175 Honeywell | 16 Ch Analog Output
Manufacturer: Honeywell
Product No.: 51308353-175
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
CC-TAOX11 (51308353-175) is a Honeywell 16-Channel Analog Output Module. It delivers 4-20 mA signals to field actuators, valves, and positioners. This module ensures precise control for Experion PKS.
Technical Specifications
| Manufacturer | Honeywell |
| Product Number | CC-TAOX11 / 51308353-175 |
| Product Type | Analog Output Module |
| Output Type | 4-20 mA (sourcing) |
| Output Channels | 16 channels (isolated) |
| Resolution | 15 bits plus sign |
| Accuracy | ±0.1% of span (25°C) |
| Load Resistance | 0 to 750 Ω |
| Update Rate | 10 ms per channel |
| Operating Temperature | -40°F to 185°F (-40°C to +85°C) |
| Power Supply | 24 VDC ±10% |
| Current Consumption | 250 mA (typical) |
| Diagnostics | Open circuit & short circuit detection |
Installation Guide
Wire each channel using shielded twisted pair cable. Connect the shield to earth ground at the module end only. Do not exceed 750 Ω load resistance per channel. Verify 24 VDC supply polarity before powering the module.
Engineering Advantages
This module drives 16 independent 4-20 mA loops. Onboard diagnostics report open circuits and short circuits to Experion PKS. The CC-TAOX11 operates reliably from -40°F to 185°F, suitable for turbine halls and compressor stations.
FAQs
Q1: Can this module output 0-20 mA?
A1: No. The CC-TAOX11 supports 4-20 mA only. 0 mA indicates a loop fault.
Q2: What happens if a channel overloads?
A2: The module reports a short circuit diagnostic. Each channel resets automatically after fault removal.
Q3: Is HART protocol supported?
A3: No. This module transmits 4-20 mA analog signals only. Use a HART multiplexer for digital communication.
Additional Specifications
- Gray
- Black
- Silver
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
